English
4. MACHINE DESCRIPTION
4.1. USAGE CONDITIONS
This machine has been designed for pumping clean
water at a maximum temperature of 35C. Do not use
this pump to pump other liquids different to clean
waters such as sea water, dirty water, petrol, oils,
solvents, food liquids (milk, soft drinks, etc) or residual
waters. This machine is for private domestic use in
domestic water installations and domestic watering
systems.
This machine is for private use in domestic water
installations, watering systems or similar installations.
It has not been designed for continuous use.
4.2 MACHINE FUNCTIONING
This pressure group is formed of a pump that
impulses water at pressure and automatic pump that
starts and stops the pump.
When starting to use the pressure group, the pump
provides pressure to the water circuit. Whilst there is
water in the system thanks to for example an open
water tap, the pump will provide water pressure
without stoppage. If, the tap were to be closed, the
automatic pump will cut the current to the engine
and the pump will stop. When the tap is opened, the
automatic pump will connect, the engine will start to
turn the pump that will provide pressure to the circuit.
In this way, the machine will provide pressure and
water flow constant when the machine is working and
stopping the pump depending on the necessities.
4.3. DETAILED DESCRIPTION OF THE PRODUCT
1. Transport handlee
2. ON/OFF Switch
3. Cable
4. Body of the pump
5. Aspiration
6. Impulsion
7. Filling cap
8. Emptying cap
9. Automatic pump
10. Led indicators
22/92