3. Operation (For Wired Remote controller)
3.6.3 Energy saving option
Energy saving option
No occupancy energy save
Room occupancy energy save
No occupancy Auto-OFF
Setting display: SELECT
Cursor
RETURN SELECT
MENU
HOLD
Energy saving option
No occupancy energy save
Cooling/Heating
Select: SELECT
RETURN SELECT
MENU
HOLD
Energy saving option
Room occupancy energy save
Cooling/Heating
Select: SELECT
RETURN SELECT
MENU
HOLD
Energy saving option
No occupancy Auto-OFF
120
min.
Select: SELECT
en
Time
RETURN SELECT
MENU
HOLD
18:47 Thu
Shut down by
No Occupancy Auto-OFF
31/Dec 12:59
RETURN SELECT
MENU
HOLD
11
1 Select the desired menu with the
[F1] or [F2] button.
No occupancy energy save
If there are no persons in the room
for 60 minutes or more, energy-
saving operation equal to 2 °C,
4 °F is performed.
Room occupancy energy save
If the occupancy rate decreases
ON
to approximately 30% of the maxi-
OFF
mum occupancy rate, energy-
saving operation equal to 1 °C,
2 °F is performed.
No occupancy Auto-OFF
If there are no persons in the
room for the set amount of time
(60–180 minutes), the operation
is automatically stopped.
2 When No occupancy energy save
or Room occupancy energy save
is selected
Select the setting with the [F4]
button.
OFF → Cooling only → Heating
only → Cooling/Heating → OFF...
After changing the setting, press
ON
the [SELECT/HOLD] button to
OFF
save the setting.
OFF: The function is disabled.
Cooling only: The function is ena-
bled only during cooling mode.
Heating only: The function is ena-
bled only during heating mode.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
ON
OFF
3 When No occupancy Auto-OFF is
selected
Set the time with the [F3] or [F4]
button.
―: The setting is disabled (the op-
eration will not stop automatically).
60 – 180: The time can be set in
10-minute increments.
ON
OFF
4 The message at left will appear
if the operation was stopped
automatically by the No occupancy
Auto-OFF setting.
ON
OFF
3.6.4 Seasonal airflow function
Seasonal airflow
Seasonal airflow
Seasonal airflow
Seasonal airflow
Cooling/Heating
Cooling/Heating
Select: SELECT
Select: SELECT
ON
RETURN SELECT
MENU
OFF
HOLD
Notes:
Any person at the following places cannot be detected.
● Along the wall on which the air conditioner is installed
● Directly under the air conditioner
● Where any obstacle, such as furniture, is between the person and
the air conditioner
A person may not be detected in the following situations.
● Room temperature is high.
● A person wears heavy clothes and his/her skin is not exposed.
● A heating element of which temperature changes significantly is
present.
● Some heat sources, such as a small child or pet, may not be sensed.
● A heat source does not move for a long time.
The 3D i-see Sensor operates once approximately every 3 minutes
to measure the floor temperature and detect persons in the room.
● The intermittent operating sound is a normal sound produced when
the 3D i-see Sensor is moving.
Notes:
During swing operation, the directional indication on the screen
●
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
●
In the following cases, the actual air direction will differ from the
●
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
3.7. Ventilation
For LOSSNAY combination
■
The following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
Notes: (for wireless remote controller)
Running the ventilator independently is not available.
●
No indication on the remote controller.
●
1 Select the setting with the [F4]
button.
OFF → Cooling only → Heating
only → Cooling/Heating → OFF...
After changing the setting, press
the [SELECT/HOLD] button to
save the setting.
OFF: The function is disabled.
Cooling only: When the thermostat
turns off during cooling mode, the
vanes move up and down.
Heating only: When the thermostat
turns off during heating mode,
the vanes move to the horizontal
airflow direction to circulate the air.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
* In order to enable this function,
the airflow direction must be set
to "Auto".