3. Operation (For Wired Remote controller)
3.6.3 Energy saving option
Energy saving option
No occupancy energy save
Room occupancy energy save
No occupancy Auto-OFF
Setting display: SELECT
Cursor
RETURN SELECT
MENU
HOLD
Energy saving option
No occupancy energy save
Cooling/Heating
Select: SELECT
RETURN SELECT
MENU
HOLD
Energy saving option
Room occupancy energy save
Cooling/Heating
Select: SELECT
RETURN SELECT
MENU
HOLD
Energy saving option
No occupancy Auto-OFF
120
min.
Select: SELECT
en
Time
RETURN SELECT
MENU
HOLD
18:47 Thu
Shut down by
No Occupancy Auto-OFF
31/Dec 12:59
RETURN SELECT
MENU
HOLD
11
1 Select the desired menu with the
[F1] or [F2] button.
No occupancy energy save
If there are no persons in the room
for 60 minutes or more, energy-
saving operation equal to 2 °C,
4 °F is performed.
Room occupancy energy save
If the occupancy rate decreases
ON
to approximately 30% of the maxi-
OFF
mum occupancy rate, energy-
saving operation equal to 1 °C,
2 °F is performed.
No occupancy Auto-OFF
If there are no persons in the
room for the set amount of time
(60–180 minutes), the operation
is automatically stopped.
2 When No occupancy energy save
or Room occupancy energy save
is selected
Select the setting with the [F4]
button.
OFF → Cooling only → Heating
only → Cooling/Heating → OFF...
After changing the setting, press
ON
the [SELECT/HOLD] button to
OFF
save the setting.
OFF: The function is disabled.
Cooling only: The function is ena-
bled only during cooling mode.
Heating only: The function is ena-
bled only during heating mode.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
ON
OFF
3 When No occupancy Auto-OFF is
selected
Set the time with the [F3] or [F4]
button.
―: The setting is disabled (the op-
eration will not stop automatically).
60 – 180: The time can be set in
10-minute increments.
ON
OFF
4 The message at left will appear
if the operation was stopped
automatically by the No occupancy
Auto-OFF setting.
ON
OFF
3.6.4 Seasonal airflow function
Seasonal airflow
Seasonal airflow
Seasonal airflow
Seasonal airflow
Cooling/Heating
Cooling/Heating
Select: SELECT
Select: SELECT
ON
RETURN SELECT
MENU
OFF
HOLD
Notes:
Any person at the following places cannot be detected.
● Along the wall on which the air conditioner is installed
● Directly under the air conditioner
● Where any obstacle, such as furniture, is between the person and
the air conditioner
A person may not be detected in the following situations.
● Room temperature is high.
● A person wears heavy clothes and his/her skin is not exposed.
● A heating element of which temperature changes significantly is
present.
● Some heat sources, such as a small child or pet, may not be sensed.
● A heat source does not move for a long time.
The 3D i-see Sensor operates once approximately every 3 minutes
to measure the floor temperature and detect persons in the room.
● The intermittent operating sound is a normal sound produced when
the 3D i-see Sensor is moving.
Notes:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
3.7. Ventilation
For LOSSNAY combination
The following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
Notes: (for wireless remote controller)
Running the ventilator independently is not available.
No indication on the remote controller.
1 Select the setting with the [F4]
button.
OFF → Cooling only → Heating
only → Cooling/Heating → OFF...
After changing the setting, press
the [SELECT/HOLD] button to
save the setting.
OFF: The function is disabled.
Cooling only: When the thermostat
turns off during cooling mode, the
vanes move up and down.
Heating only: When the thermostat
turns off during heating mode,
the vanes move to the horizontal
airflow direction to circulate the air.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
* In order to enable this function,
the airflow direction must be set
to "Auto".