Problem
Pilot will not stay on
Burner will not light
In case of any faults or problems of assembly or use, please don't try to modify the appliance by yourself. Contact your supplier or distributor to solve it.
TECHNICAL DATA
CONSTRUCTION AND CHARACTERISTICS
• Transportable terrace/garden heater with gas cylinder housing.
• Casing in steel with powder-coating or in stainless steel.
• Gas hose connections with metal clamp . Heat emission from reflector.
SPECIFICATIONS
• Use propane, butane or their mixtures gas only.
• Max. wattage: 9000 W
• Min. wattage: 5000 W
• Battery type: 1 x AAA 1.5V
Country:
BE, ES, FR, IT, PT
Appliance category:
G30 (Butane)
Gas type and
pressure:
G31 (Propane)
Power:
Injector (mm):
PIN Number:
• Use the proper regulator according to gas pressure as shown in the table above.
• The marking, for example, 1.5 on the injector, indicates that the size of injector is 1.5 mm.
• The hose and regulator assembly must conform to local standard codes.
• Gas pressure should meet the corresponding appliance category in Specification table.
• The appliance requires approved hose in 1.4m length.
• The regulator (complying with EN16129:2013 and the national regulation) must have the correct pressure corresponding to the appliance category.
• Use a 28-30mbar regulator for butane/propane under the category I3B/P(30).
• It's recommended to use a flexible hose that approved by EN16436: 2014.
DISPOSAL
Do not put your used batteries, nickel cadmium, rechargeable, round cell or starter batteries in with your household rubbish. Take them to an appropriate
disposal / collection site.
WARRANTY
A statutory warranty applies for this product.
Damages caused by wrong treatment or operation, by false placement or storage, improper connection or installation, as well as force or other external influences
are not covered by this warranty. We recommend careful reading of the operating instructions as it contains important information.
Note:
1. In case this product does not function correctly, please firstly check if there are other reasons, e.g. for electrical appliances interruption of the power supply, or
generally incorrect handling are the cause.
2. Please note that, where possible, the following documents or rather information should be provided together with your faulty product:
– Purchase receipt
– Model description/Type/Brand
– Describe the fault and problem as detailed as possible
In the case of a claim for guarantee or defects, please contact the seller.
GWL 8/14 EN
Probable cause
• Debris around pilot
• Loose connections
• Thermocouple bad
• Gas leak in line
• Gas pressure is low
• Gas pressure is low
• Opening blocked
• Control not ON
• Thermocouple bad
• Pilot light assembly bent
• Burner not in correct location
BG, CZ, HR, HU, IT, NL, RO, TR
I
3+(28-30/37)
28-30 mbar
G30 (Butane)
G31 (Propane)
37 mbar
or their mixture
9.0 kW(Hs)
655 g/h
• Clean dirty area
• Tighten connections
• Replace thermocouple
• Check connections
• Cylinder is empty. Refill it
• Cylinder is empty. Refill it
• Remove blockage and clean opening
• Turn the knob
• Replace the thermocouple
• Position correctly
• Position correctly and try again
I
3B/P(30)
G30 (Butane)
28-30 mbar
G31 (Propane)
or their mixture
9.0 kW(Hs)
655 g/h
1.5
0063CN7201
Art. No.:
GPH6000S
QA21-0000000556
11
Solution
PL
I
3B/P(37)
G30 (Butane)
37 mbar
G31 (Propane)
or their mixture
10.5 kW(Hs)
764 g/h
220225
MCC Trading International GmbH
Schlüterstraße 5
40235 Düsseldorf
Germany
Made in China
GB
AT, DE, NL, SK
I
3B/P(50)
50 mbar
12.5 kW(Hs)
910 g/h

Publicidad