Descargar Imprimir esta página

Husqvarna DC 2-48 Manual Del Usuario página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Remove the chain cover.
3. Push the chain to examine the tension. If you can
push the chain a distance of 5 mm/0.2 in., the
tension is correct.
4. Loosen the nuts.
5. Move the chain wheel to adjust the tension.
6. Tighten the nuts.
7. Install the chain cover.
To adjust the gland seals of the rotating
valves
If there is a leakage of dust at the gland seals, it is
necessary to tighten the gland seals. There are gland
seals on each side of the 2 rotating valves.
1. Stop the product. Refer to
page 11 .
18
To stop the product on
2. Make sure that the bushings (A) are vertical and not
at an angle.
A
C
3. Tighten the nuts (B) a half turn.
CAUTION:
too much. The gland seals can become
damaged.
4. Make sure that the distance (C) is the same on the
left and the right side.
5. Start the product and make sure that there is no
leakage of dust at the gland seals.
To replace the rotating valve seals
WARNING:
protection when you replace the rotating
valve seals. Refer to
equipment on page 6 .
1. Stop the product. Refer to
page 11 .
2. Make sure that the power supply is disconnected.
B
Do not tighten the nuts
Use approved respiratory
Personal protective
To stop the product on
2121 - 002 - 04.07.2023

Publicidad