Electrical Connection
This appliance must be earthed.
This appliance is designed to be connected to a 220-240V, 50Hz-60Hz AC electricity supply.
The wires in the mains lead are coloured in accordance with the following code;
- Green/yellow = Earth
The wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol.
Gas adjustment
Take precautions on the operations and adjustments to be carried out when
converting from one gas to another.
All work must be carried out by a qualified technician.
Before you begin, turn off the gas and electricity supply to the appliance.
1
Change the injector of the burners.
2
Adjustment of minimum level of the flame.
Do not dismantle the tap shafe: in the event of a malfunction, change the whole tap.
Before placing the burners back on the top place, make sure that the injector is not blocked.
A full operational test and a test for possible leakages must be carried out after gas conversion,
(such as soap water or gas detector).
After completing conversion, a qualified technician or installer has to mark "V" on the right gas
category to match with the setting in rating plate. Remove the previous setting "V" mark.
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and
replace it with the stipulated injector for new gas supply.
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly
tighten the injector in place.
Injector
Turn the taps down to minimum.
Remove the knob from the tap and place a small bladed
Control handle
screwdriver in the centre of the Adjustment screw.
The correct adjustment is obtained when the flame has a length of
Tap
about 3-4 mm.
Sealing ring
Repeat this process for each one of the gas taps.
- Blue = Neutral
- For butane/ propane gas, the adjusting screw must.
- be tightly screwed in.
- Refit the control knob.
Make sure that the flame does not go out by quickly turning from
maximum flow to minimum flow. If it does then remove the
control knob and make further adjustments to the gas flow,
testing it again once the adjustment has been made.
EN-18
- Brown = Live