SAVE AND LOAD WELDING SETTINGS
• JOB IN / JOB OUT
The current settings are automatically saved and loaded at start up.
On top of the current settings, it is also possible to save and load the «JOB» settings.
There are 50 JOBS by welding process, the memorisation applies to:
- The main setting,
- The secondary setting (MMA, TIG),
- The sub-processes and button modes.
Save a setting « JOB IN » :
- Press the button
(Fig 2 - 7), select using the scrollwheel
- Validate by pushing the SCROLLWHEEL BUTTON
- The screen flashes to point out a memory slot (01 to 50),
- Use the scrollwheel to select the destination memory slot
- Validate by pushing the SCROLLWHEEL BUTTON
- The choice is now saved and exit.
Recall an existing setting « JOB OUT » :
- Press the button
, select using the scrollwheel
- Validate by pushing the SCROLLWHEEL BUTTON
- The screen flashes to point out a memory slot (01 to 50),
- Use the scrollwheel to select the destination memory slot
- Validate by pushing the SCROLLWHEEL BUTTON
- The choice is now saved and exit.
• QUICK LOAD « q.L. » :
The Quick Load is a mode to recall a JOB (50 max) when not welding and only available when using TIG.
The JOB recalls are done by holding and releasing the torch buttons for a brief moment (<0.5s).
Access to this mode is done by pressing the menu
mode by entering the last JOB number of the list to recall (the list starts at the first JOB). At least 2 JOBS must be saved prior to that.
Ex : if the JOBS 2, 5, 7 and 10 have been created and that the user has entered number 7, then the JOBS recalled will be 2, 5 and 7.
On activation of this mode, the first JOB is recalled and displayed on the screen (on this example : JOB2).
The different JOBs are queued in for recall : when the last JOB is reached, (for example : JOB7), the next JOB recalled will be the first one (on the
example : JOB2).
Welding is activated by pressing the button for longer than 0.5s.
What is displayed by MMI interface:
- The JOB is displayed permanently as well as the settings (TIG LIFT/HF, 2T/ 4T../ Pulse/ Spot...).
- The cycle is accessible and amendable (the JOB can be changed*),
- The menus are accessible and are amendable. Example :
• JOB 5, amendable, SAVE IN / JOB 5, the JOB is saved and amended in line with the new settings entered.
• JOB 5, amendable, SAVE IN / JOB inexistent, it will be taken into account in the current q.L if and only if this new JOB X is below the number of
the JOB entered.
- The recall of the JOB is inactive when navigating in the welding cycle or one of the two menus,
* A JOB is amended by action on the interface (welding settings, JOB recall...), the welding is authorised using the new settings entered. If a JOB
recall is done, then the first JOB of the list if recalled.
CHAIN « Chn » :
The chain is a recall mode for complex JOBs (50 max) and only available when using the TIG STD and PULSE processes (all the JOBs defined in 2T
are forced in 4T) :
- Outside . On reaching the last item in the list, the selection goes back to the first item.
- Welding is activated by pressing the top button for 0.5s where in the standard mode, it is activated by simply pressing this button.
- During welding, briefly releasing the buttons (less than 0.5s) allow to recall a consecutive and defined JOB number, also called sequence and starting
from the JOB previously recalled when not welding.
Access to this mode is done by pressing the menu
mode by entering a number of JOBS part of its sequence. At least 2 JOBS must be saved prior to that.
Spot welding jobs (SPOT, TACK), are no longer part of the list of saved JOBS (they are transparent).