Place the device in its location and then connect its plug to a power outlet.
The screen on the control panel will light up.
Press the "POWER" button (on the device or the remote control) and the
device will turn on with the default settings, i.e. 15 minutes and 100% ozone
production.
Press the "OZONE" button to set the desired ozone percentage per hour (see
below).
Press the "TIMER" button to set the operating time of the unit depending on
the area of the room (see the table below). Each press of the button
increases the operating time by 15 minutes.
Press the "INTERVAL" button to select a 12 or 24-hour working interval.
After 40-60 minutes from the end of the operation, you can enter the room
and open the doors and windows to ventilate it.
Capacity
Room area
[m
]
2
75
150
300
450
600
750
900
1200
3.4.
Cleaning and maintenance
a)
Before cleaning, adjustment or replacement of accessories, and when the
appliance is not in use, unplug the power cord from the mains and wait for the
rotating parts come to a stop.
b)
Use only non-corrosive cleaning agents for cleaning the surfaces.
c)
Store the unit in a dry and cool place protected from moisture and direct
sunlight.
d)
Do not spray the unit with a stream of water or immerse it in water.
e)
Make sure that no water enters through the ventilation openings in the casing.
f)
The ventilation holes and the ceramic plate (its radiator) should be cleaned
with a brush and compressed air of a lower pressure.
g)
Use a soft cloth for cleaning.
h)
Do not use sharp and/or metal objects (e.g. wire brush or metal spatula) for
cleaning as they may damage the surface of the appliance material.
10 g/h
Working
Working
time [min]
time [min]
60
120
240
-
-
-
-
-
20 g/h
30 g/h
Working
time [min]
30
60
120
180
120
240
160
-
200
-
240
-
40 g/h
Working
time [min]
20
15
40
30
80
60
90
120
150
180
-
240

Publicidad