Specifications
Power requirements: AC100-240V, 50/60Hz
Power consumption:
28VA (for 100V), 39VA (for 240V)
Output voltage: DC8.4V 1.5A
Operating temperature: 0 ~ 40°C
{32 ~ 104°F}
Storage temperature: -20 ~ 60°C
{-4 ~ 140°F}
Dimensions: Approx. 56 × 44 × 107 mm
{2.2 × 1.7 × 4.2 in} (W × H × L)
Mass: Approx. 140 g {0.31 lb}
Specified battery: LIP-2500 (Exclusive battery
for EPSON TM-P60)
EMC and Safety Standards
Applied
Product Name:
Battery charger
Model Name:
OT-CH60
The following standards are applied only to the battery
chargers that are so labeled.
Europe:
CE Marking
Safety DEMCO (EN 60950-1)
North America:
EMI: FCC/ICES-003 Class B
Safety: UL1310
Argentina:
Argentina Safety
Japan:
PSE-mark
Oceania:
EMC: AS/NZS CISPR22 Class B
Safety : AS/NZS 60950-1
CE Marking
The battery charger conforms to the following
Directives and Norms:
Directive 2004/108/EC EN 55022 Class B
Directive 2006/95/EC
FCC Compliance
Statement For American
Users
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
4 OT-CH60 Battery Charger User's Manual
/CSA C22.2 No. 223 (c-UL)
EN 61000-3-2
EN 61000-3-3
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-11
EN 60950-1
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and
receiver.
-Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV
technician for help.
For North American
Use only CSA/UL Certified power supply cord set,
Polarized, Type SPT-2 or heavier, minimum No. 18 AWG
copper, rated 125 or 250 V, minimum 1 A, minimum 6 ft
(1.8 m), maximum 10 ft (3 m) long.
For Other Countries
Must comply with requirements set out by the Safety
Approval/Certification Organization in each county of
use.
For Canadian Users
This Class B digital apparatus complies with Canadian
ICES-003.
Türkiye'deki kullanýcýlar için
EEE Yönetmeliğine Uygundur.
Для українських користувачів
Обладнання відповідає вимогам Технічного
регламенту обмеження використання деяких
небезпечних речовин в електричному та
електронному обладнанні.
Indication of the manufacturer
and the importer in accordance
with requirements of directive
2011/65/EU (RoHS)
Manufacturer: SEIKO EPSON CORPORATION
Address: 3-5, Owa 3-chome, Suwa-shi, Nagano-ken 392-
8502, Japan
Telephone: 81-266-52-3131 Fax: 81-266-52-8409
Importer: EPSON EUROPE B.V.
Address: Azië building, Atlas ArenA, Hoogoorddreef 5,
1101 BA Amsterdam Zuidoost, The Netherlands
Telephone: 31-20-314-5000