The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
The Fuse
To reset the triggered built-in fuse, wait 5 minutes and then gently press the reset button.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Fitting lamps:
OMNILUX MR-16 12V/35W GX-5.3 SP 12° red
OMNILUX MR-16 12V/35W GX-5.3 SP orange
OMNILUX MR-16 12V/35W GX-5.3 SP 12° yellow
OMNILUX MR-16 12V/35W GX-5.3 SP 12° green
OMNILUX MR-16 12V/35W GX-5.3 SP 12° blue
OMNILUX MR-16 12V/35W GX-5.3 SP violet
Maximum ambient temperature t
Maximum housing temperature t
Fuse:
Please note: Every information is subject to change without prior notice. 17.06.2003 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
:
a
(steady state):
B
230 V AC, 50 Hz
500 W
510 x 395 x 410 mm
22.5 kg
Order No.
91205770
(included)
91205771
91205772
91205774
91205776
(included)
91205778
45° C
110° C
5 A, 250 V