3) INSTALLATION, POSITIONING AND FIXING
Art. VIIP-PE7T can be installed outdoors, within the indicated temperature limits, and following the instructions in this document.
The recommended installation height of the product is: upper limit at 1.6 m from the ground (see figure 1). Refer to Figures 1 and 2 to install the devices. Install the product so that the camera of the
device is not blinded by direct light sources (street lamps, headlights or direct sunlight) that would compromise its operation.
Note: the devices are equipped with white LEDs that illuminate the subject positioned at a maximum distance of 1m in case of poor lighting.
The AVE video-intercom system complies with the strictest product standards both as regards performance and safety requirements and compliance with the relevant environmental tests. It also
contains advanced video surveillance functions (which can be activated during installation of the system) that may be subject to Regulation 679/2016 ("GDPR") and the General Provision of the Video
surveillance authority of 8 April 2010. Since these indications establish specific obligations for the protection of privacy, we draw attention to the fact that the installation is carried out according to
the current laws and legislative decrees on "privacy".
The faces acquired for the "Face Unlock" function are stored only inside the VIIP-PE7T device and cannot be accessed from the internal stations of the apartments connected to it. The images can be
deleted from the device via a special password-protected menu in the device itself.
4) CONNECTIONS
Below is the meaning of the connectors located on the back of the device. The layout of the connectors is as follows:
J11 connector (2 pole)
Terminal block (8 pole)
Terminal 1: +24Vdc
Terminal 1: to be connected to terminal 2 (COM)
Terminal 2: GND
Terminal 2: COM
Terminal 3: EL – with power output for
door opening
Terminal 4: not used
RJ45 connector
Terminal 5: GND for door opening
Terminal 6: GS - door open sensor input
Terminal 7: DOOR – room door opening
LAN connection and standard
input
48Vdc PoE power supply
Terminal 8: GND – reference for GS and
DOOR inputs
5) DOOR OPEN SENSOR INPUT (GS)
It is possible to monitor the "Door open" status by connecting a normally open sensor (e.g. AF902, AF903, etc... closed when the door is closed) to the GND and GS terminals. If enabled, 30 seconds
after the device has been switched on and if the door remains open for more than 2 minutes, the outdoor station will beep until the door is closed again. The indoor stations emit an optical signal
(depending on the model) to warn of the "Door open" alarm.
6) DOOR OPENING BUTTON INPUT (DOOR)
Between the "DOOR" input and the GND terminal, it is possible to connect a normally open button (e.g. 441005): a short press acts on the relay EL power output (Unlock 1).
7) GATE OPENING BUTTON INPUT (GATE)
Between the "GATE" input and the GND terminal, it is possible to connect a normally open button (e.g. 441005): a short press acts on the relay clean contact NO power output (Unlock 2).
Use a normally open contact, referred to the GND terminal, with reinforced insulation between dangerous voltages.
8) BASIC FUNCTIONS OF THE DEVICE
8.1) CALL TO INDOOR STATION WITH APARTMENT NUMBER
After entering the room number, click on
If the indoor monitor is online, the outdoor station will emit a call forwarded sound. If, on the other hand, there is no answer within 30 seconds, the call will end automatically.
If the monitor is offline, there will be no confirmation tone and a no call message will appear.
8.2) CALL TO INDOOR STATION WITH NAME LIST
If the name list is enabled, click on the
If the indoor monitor is online, the outdoor station will emit a call forwarded sound. If, on the other hand, there is no answer within 30 seconds, the call will end automatically.
If the monitor is offline, there will be no confirmation tone and a no call message will appear.
8.3) CALL CONCIERGE
If enabled, the
icon is visible on the main screen. By pressing it, the visitor can call the concierge directly (if present).
8.4) UNLOCK 1 (HIGH ENERGY OUTPUT: EL / GND TERMINALS)
8.4.1) ACTIVATION BY CARD
Place a registered card in the card reading area to unlock the door.
8.4.2) ACTIVATION BY BUTTON
On the DOOR and GND terminals of the Outdoor Station, it is possible to wire a normally open button, which residents can simply press to unlock the door.
8.4.3) ACTIVATION BY PUBLIC PASSWORD
1. In the Facial Recognition interface, click on
2. Select Public password unlock enter the public password: 666666 (default password, can be changed as required)
8.4.4) ACTIVATION BY USER PASSWORD
3. In the Facial Recognition interface, click on
4. Select User password unlock
5. Enter the apartment number and the password, then click on
8.5) UNLOCK 2 (NORMALLY OPEN CONTACT: NO / COM TERMINALS)
8.5.1) ACTIVATION BY BUTTON
On the GATE and GND terminals of the Outdoor Station, it is possible to wire a normally open button, which residents can simply press to unlock the gate.
9) SETTINGS
9.1) STANDBY INTERFACE
IP network
availability
Delete
Name list
Terminal block (6 pole)
Terminal 1: NO normally open contact for
gate opening (unlock2)
Terminal 2: COM normally open contact
for gate opening (unlock2)
Terminal 3: GATE normally open button
input for gate opening
Terminal 4: GND reference for GATE and
RS485 interface
Terminal 5: DA – RS485 interface
Terminal 6: DB – RS485 interface
to start the call.
icon to display the list, select the name or scroll through the pages until you find the name you are looking for.
to select the unlock mode.
to select the unlock mode.
9.2)
ACCESS TO THE SETTINGS INTERFACE
Starting from standby mode --- Click on
click on
---- enter the room number "0000", the password
"222222" (default configuration password).
Stands for: Outdoor station
building 1 - Unit 1
Numeric keyboard
Confirm
Unlock menu
, then
to go to the settings access interface
4
9.3)
SETTINGS INTERFACE
After entering the correct password, click on
access the settings interface; the resident can
choose specific settings by clicking on the option.
to