Descargar Imprimir esta página

Crafstman 919.167280 Manual Del Propietário página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

Air Compressor
Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the air
outlet.
Check Valve: When the air compres-
sor is operating, the check valve is
"open", allowing compressed
air to
enter the air tank. When the air com-
pressor reaches "cut-out"
pressure,
the check valve "closes", allowing air
pressure to remain inside the air tank.
Pressure Release Valve: The pres-
sure release valve located on the side
of the pressure switch, is designed
to automatically
release compressed
air from the compressor
head and the
outlet tube when the air compressor
reaches "cut-out"
pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops running, air will be heard
escaping from this valve for a few
seconds.
No air should be heard
leaking when the motor is running or
after the unit reaches "cut-out"
pressure.
Motor Overload
Protector:
The
motor has an automatic reset ther-
mal overload protector. If the motor
overheats for any reason, the overload
protector will shut off the motor. The
motor must be allowed to cool down
before restarting.
The compressor
will
automatically
restart after the motor
cools.
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to
"OFF",
Before
First
Start-up
Risk of Unsafe
.
_
Operation.
Serious
damage may result if the following
break-in instructions
are not closely
followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor
pump has been replaced.
1.
Make sure the On/Auto/Off lever
is in the "OFF" position.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this manual.)
3.
Open the drain valve fully
(counterclockwise)
to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
NOTE: Always drain tank on a wash-
able surface or in a suitable con-
tainer to prevent damaging or staining
surfaces.
13-ENG
A16751

Publicidad

loading