Descargar Imprimir esta página

Goodyear GY 08248SOF Manual De Usuario página 31

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
English
Owner´s manual
Waste electrical products should not be disposed of with normal household waste.
Recycle at appropriate facilities. Consult your local authority or retailer for recycling
advice.
Do not place packaging in ordinary garbage for disposal, be sure to recycle the
cardboard. Recycle unwanted materials instead of disposing of them as waste. All
tools, hoses and packaging should be sorted, taken to the local recycling center and
disposed of in an environmentally safe manner.
Air filter
Check that the air filter is clean. To service the filter:
8. TROUBLESHOOTING
Problem
Compressor does not
start.
1. Remove the filter housing cover.
2. Remove the filter, in case it is clogged.
3. Replace the filter.
ATTENTION: Paper filters cannot be washed.
4. Replace the cover.
Possible cause
The unit is plugged into the extension
cord.
There is no electric current.
Fuse blown.
Open circuit breaker.
Thermal overload.
Defective pressure switch.
Motor winding shorted or open.
Solution
Remove the extension cord or use a
heavier gauge extension cord.
Check that it is properly plugged in /
Check fuse - circuit breaker or motor
overload.
Replace blown fuse.
Press again.
Unplug and allow motor to cool before
attempting to restart.
Replace circuit breaker.
Replace motor.
31

Publicidad

loading

Este manual también es adecuado para:

Gy 08248sofsGy 08248sofh