93001i-EU - 3000W PORTAbLE INvERTER GENERATOR
Problem
Engine starts and shuts off right
away.
Both CO Shield
LEDs not
®
blinking 10 times upon start up.
Generator cannot supply enough
power or overheating.
Engine is running but no AC
output.
Engine hunts or falters.
Repeated circuit breaker tripping.
For other issues and technical support:
Technical Support Team
service@bpeholdings.co.uk
Cause
If equipped, when CO Shield® shutoffs
occur due to accumulating carbon
monoxide (CO) and if the red LED light
blinks on the panel.
If equipped, when CO Shield® shutoffs
occur due to system fault and if the
yellow LED light blinks on the panel.
Starting the generator within 1 minute
after being manually shutoff, not a CO
shutoff event.
Generator is overloaded.
Dirty air filter.
Choke in wrong position.
Poor cord connection.
Circuit breaker is open.
Faulty brush assembly.
Loose wiring.
AC Overload: Button illuminated red
Other.
Engine governor defective.
Dirty fuel valve.
Carburetor is dirty and running lean.
Choke in wrong position.
Overload.
Faulty power cords or device.
Circuit breaker still too hot.
Solution
Move generator to an open, outdoor area. Point exhaust
away from people and buildings. Move to fresh air and get
medical help if sick, dizzy, or weak.
Make sure there are no objects creating obstructions
within 5 feet of the generator. Obstructions in the vicinity
of the generator may trap carbon monoxide emissions
near the generator and cause the engine to shutoff.
If the generator's exhaust is facing into the wind, the
exhaust may be blown back into the generator's operating
area, creating an accumulation of CO emissions and
triggering an engine shutoff. To avoid an engine shutoff,
turn the generator 45° in either direction to allow the
exhaust emissions to blow away from the generator. If
engine shutoff events continue, readjust and align the
exhaust with the wind direction to blow away from the
generator.
Start by confirming yellow LED light blinks when/if
generator shuts off. If CO Shield® continues to sense the
fault and shuts off, contact technical support.
Wait 1 minute before trying to restart the generator. The
LEDs should then blink ten (10) times.
Review load and adjust. See "Connecting Electrical
Loads."
Clean or replace air filter.
Move EZ Start Dial to the RUN position.
Check all connections.
Reset circuit breaker. Check all circuit breakers.
Replace brush assembly (Service Center).
Inspect and tighten wiring connections.
Reduce AC load and press Overload Reset Button until
illuminated green.
Contact the help line.
Contact the help line.
Clean the fuel valve.
Contact the help line.
Move EZ Start Dial to the RUN position.
Review load and adjust. See "Connecting Electrical
Loads."
Check for damaged, bare or frayed wires. Replace
defective device.
Let unit sit for 5 mins.
29
TROUbLESHOOTING