Air Compressor
Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor
has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
compressor
is operating, the check
valve is "open", allowing compressed
air to enter the air tank.
When the air
compressor
reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Pressure Release Valve: The
pressure release valve located on the
side of the pressure switch, is
designed to automatically
release
compressed
air from the compressor
head and the outlet tube when the air
compressor
reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restar_ freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds.
No air should be heard leaking when
the motor is running or unit reaches
"cut-out"
pressure.
Valve
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to
"OFF".
Before
First Start-up
Break-in
Procedure
_;_"_
Serious damage
may result if the
following break-in instructions are
not closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor
pump has been
replaced.
1.
Make sure the On/Auto/Off
lever
is in the "OFF" position.
NOTE: Pull coupler back until it clicks
to prevent air from escaping through
the quick connect.
On/Auto/
Off Lever
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph
in the
Installation section of this
manual.)
3.
Open the drain valve fully
(counterclockwise)
to permit air
to escape and prevent air
pressure build up in the air tank
during the break-in period.
4.
Move the On/Auto/Off
lever to
"ON/AUTO"
position. The
compressor
will start.
13_ ENG
D28409