The installation must have two Class A Ground-Fault Circuit-Interrupters (GFCI). The GFCI protects against line-to-
ground shock hazard. Use a 120 V, 15 A, 60 Hz dedicated service for the blower. Use a separate 120 V, 15 A, 60 Hz
dedicated service for the bubble heater.
If the blower supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified
persons in order to avoid a hazard.
Product Notices
IMPORTANT! The recommended operating pressure for this system is 35-60 psi (241-414 kPA).
NOTICE: Keep the area around the blower clean and free of debris. Verify that the area around the blower is free of
sawdust, insulation, dirt, and other small loose debris. Such material can block the blower air ducts and reduce the air
flow through the blower.
NOTICE: This product contains an automatic water purge mode that turns the blower on for 5 minutes after the unit is
turned off and drained.
Tools and Materials
1/2 NPT Brass
1/2"
100% Silicone Sealant
Plus:
* Do not use gypsum cement.
• Conventional Woodworking Tools and Materials
• Drop Cloth
• Construction Adhesive (Optional)
• Cement* or Mortar (Optional)
• 2x4s
• Plastic Film (Optional)
• 1/8" (3 mm) Spacers
1512796-2-A