REQUIRED VOLUME OF ROOM AND VENTILATION SURFACE:
VOLUME OF LIVING ROOM
84 cubic meters
VENTILATION
Your heater consumes oxygen while it is in operation. For that reason, adequate
ventilation should be provided in rooms in which the heater is used. This ensures
the removal of products of combustion and allows the entry of replacement air.
Adequate ventilation should considerably reduce the possibility of condensation
occurring. The following table shows the smallest sizes of room suitable for each
heat setting and the ventilation surface, which should be provided.
CONNECTING THE GAS CYLINDER
Use an approved regulator according to gas supply pressure and approved tubing
having a length of 50cm and in no case longer than 1m. When connecting the
regulator to the container avoid twisting of hose.
Slowly open the valve of the container and check if there is any gas leakage by
brushing the connections with soapy water. NEVER USE A MATCH! A gas leakage
forms the bubbles. In the event of gas leakage, the appliance should be turned off
by closing the valve and the regulator disconnected from the bottle. Place
container in its proper space and attach the rear cover.
HOW TO CHANGE LPG CONTAINER
1. Container must be replaced in a flame-free atmosphere.
2. Do not smoke while changing the container.
3. When you needed to replace your empty container, turn off gas container's
valve.
4. Make sure that the heater is extinguished completely.
5. Remove the regulator from the empty container.
6. Following the steps described in "Connecting the container" to connect a
filled one.
IMPORTANT
1. It is important that all gas connections have been correctly connected to prevent
any leakage. Use soapy water instead of a match for gas leakage checking.
2. Put your container always in upright position. Using the container in horizontally
laid down position may damage your heater and create serious results.
3. If a newly filled container is used, ignition might impair as there may be some
inert gas present in the container. In this case, change the container with
another one which is partially used.
4. When you light your heater for the first time or if it has been a long time since
you used it last time. Please be noted that first light your heater in open air
(garden or balcony). Take your heater inside after 15 minutes operation.
5. Do not use your heater while sleeping. Do not use your heater in high-rise flats.
Do not use your heater in basements, bathrooms or bedrooms.
6. This appliance requires a hose and a regulator, check with your gas supplier.
Please seek advice from your gas and regulator supplier so as to use correct hose.
The guard on the appliance is to prevent risk of fire or injury form burns and no
part of it should be permanently removed.
VENTILATION SURFACE
Low level
High level
105 cm 2
4
105 cm 2
V.1