Installation Guide
9 . Locate hooks at top of front part into top of back
plate and lower into position and tighten retaining
screw .
2 . Dimensions and Wiring
See fig . 4 for dimensions and fig . 5 for wiring diagram
on page 55 .
3 . RF Pairing
1 . Ensure power to RX1-S receiver is switched on and
batteries are inserted into thermostat .
2 . Ensure the display is illuminated . If not, press any
button once to illuminate . Press and hold M button
on thermostat for 6 seconds until display changes to
show setting options .
3 . Release and press M button until setting option 10
is shown .
4 . Press > button to change setting to 01 .
5 . Press the upper part of the setting ring for
RET2001RF and
ting . RF aerial icon will flash to indicate thermostat is
in learn mode .
6 . Press both PROG and CH buttons on RX1-S until
button LEDs flash .
7 . If pairing is successful RF icon on thermostat will
stop flashing and remain on .
8 . If pairing is not successful try moving thermostat to
alternative position and retry .
Danfoss Heating Solutions
RET2001RF & TP5001RF
for TP5001RF to accept the set-
VISUQ14F
EN
5