To avoid personal injury, always shut off and unplug the
compressor and relieve all air pressure from the system before performing any
service on the air compressor.
To ensure
efficient
operation
and
longer
life of the
air
compressor
unit,
a
routine
maintenance
schedule
should
be
followed.
The following
schedule
is
geared toward
a consumer
whose
compressor
is used
in a normal
working environment on a daily basis.
This compressor is
items to Check/Change
Afcai
Rli
Q_rwT
jtc
Mt cp jj Sl gfT_lsj
Af cai
B_
Rli
Afcai
NrrucpArr_odrpB
k
ec
Before
each use
or daily
X
X
X
X
equipped with an automatic reset thermal overload protector which will shut off
motor if it becomes overheated, if the thermal overload protector is actuated, the
motor must be allowed to cool down before start-up is possible.
NOTE: The motor will automatically restart without warning if the unit is left
plugged in to an outlet with the Auto-On/Off switch in the on position.
DRAINING
THE TANK
Condensation
will accumulate
in the
tank. To prevent corrosion of the tank from the inside,
this moisture must
be drained
at the end of every
workday. Be sure to wear protective eyewear. Relieve the
air pressure in the system and open the drain valve on
the bottom of the tank and tilt tank to drain.
Figure 5
NOTE: In cold climates, drain the tank after each use to reduce problems with
freezing of water condensation.
CHECKING
THE SAFETY
VALVE (Figure 5)
Check the safety valve by performing these three steps:
1.
Plug the compressor in and run until shut-off pressure is reached.
2.
Wearing safety glasses, pull out on the safety valve ring to release pressure
from the tank.
3.
The safety valve should close automatically at approximately
at 40-50 PSi.
if the safety valve does not allow air to be released when you pull out
on the ring, or does not close automatically, it must be replaced.
STORAGE
For storing the air compressor, be sure to do the following:
1. Turn the unit off and unplug the power cord from the receptacle.
2.
Remove all air hoses, accessories, and air tools from the air compressor.
3.
Perform the daily maintenance schedule.
4.
Open the drain valve to bleed all air from the tank.
5.
Close the drain valve.
6.
Store the air compressor in a clean and dry location.
16- ENG