Technical Data (Continued)
Protection:
Weight:
Inputs:
Outputs:
Accuracy:
6. Connecting Diagram
Inputs
1: 10 ... 30 V DC
2: GND_1
3: GND_2
4: Hold
7. Scope of Delivery
1 Digital display
1 Panel mounting clip
1 Bezel for clip mounting,
panel cut-out 50 x 25 mm
1 Bezel for screw mounting,
panel cut-out 50 x 25 mm
1 Gasket
1 Multilingual operating manual
Fritz Kübler GmbH Zähl- und Sensortechnik • P.O. BOX 3440 • D-78023 Villingen-
Schwenningen • GERMANY • Tel: +49 (0) 77 20 - 39 03 - 0 • Fax +49 (0) 77 20 - 2 15 64
sales@kuebler.com • www@kuebler.com
12
IP 65 front
approximately 50 g
2 front side keys for setting and programming
Hold input, optocoupler, high active
low: 0 .. 2 VDC / high: 4 .. 30 VDC
Current output 0 ... 24 mA, increment 10 μA
Load 20 mA up to < 500 Ohms, > 20 mA up to < 400 Ohms
Ripple: <10 mVss
Voltage output 0 ..12 V, increment 10 mV,
Load > 2 kOhms, Ripple: <10 mVss
< 0,2 % of the final value + 0,02 %/K
Outputs
5: 0 ... 24 mA (Iout)
6: GND_3
7: 0 ... 12 V DC (Uout)
Screw terminals RM5.08:
0,14 ... 1,5 mm 2 , 26 ... 16 AWG
Block diagram and connection see
point 1.4
8. Order Information
Setpoint generator 533:
6.533.012.300
9. Error Messages
Err0: Programming error, e.g.: the
value input is above ou.Hi
10. Dimensions, see folding pages