C O N T R O L P A N E L
A - On/off switch.
B - Lighting the Burner / Temperature adjustment.
C - Power indicator light.
D - Diesel level indicator light.
E - Maintenance indicator light.
F - Fault indicator light.
G
- Motor Thermal indicator light.
U SI N G
Start the cleaner by turning the selector switch "A" to pos. "I".
In this position, you can control the water temperature from
minimum to maximum, by using regulator "B".
!
W a r n in g
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
By positioning switch "A" on pos. II "Chem 50%", it activates
the supply of the detergent solution at 50% of the full capacity.
The water temperature can be set using regulator "B" at a
recommended degree of 60°C.
By positioning switch "A" on pos. III "Chem 100%", it activates
the supply of the detergent solution at 100% of the full capacity.
The water temperature can be set using regulator "B" at a
recommended degree of 60°C.
SI G N A L S A N D F A U L T S D I SP L A Y E D .
I n d ic a t or l ig h t C ) : Power is on when the indicator light is on
steady (switch "A" in pos. I); when the indicator light is flashing,
the high pressure washer is in "TSI" status.
Led Lights pressure washer running, led in scoring when wai-
ting, led flashing in "TSI" status.
I n d ic a t or l ig h t D ) : Fuel level; the light on indicates low fuel level.
I n d ic a t or l ig h t E ) : 200h programmed maintenance interval
expired. The light will go off following maintenance by the
authorised service centre.
I n d ic a t or l ig h t F ) : Fault indicator:
- 2 flashes, Micro-leak alarm.
- 3 flashes, no water alarm.
- 5 flashes, Auto-reset "TSI" status
- 6 flashes, Temperature NTC probe failure alarm.
- 7 flashes, Anti-flood alarm (1h operation).
I n d ic a t or l ig h t G ) : Motor thermal protector activated.
H I G H P R E SSU R E W A SH E R SH U T D O W N - P O SSI -
B L E F A U L T S
1 ) High pressure washer not used for more than 20 min., high
pressure washer in total stop mode (TSI).
This is signalled by indicator light C ) flashing.
2 ) Low fuel level: the burner shuts down and not hot water is
delivered.
T H E C L E A N E R
E n g l is h
The fault is signalled by indicator light D ) on steady.
3 ) 200h programmed maintenance interval expired. The light
will go off following maintenance by the authorised service
centre.
The fault is signalled by indicator light E ) on steady.
4 ) Micro-leaks detected or water nozzle clogged: the high
pressure washer shuts down.
The fault is signalled by indicator light F ) flashing.
5 ) No water: After 3 minutes of operation with no water detected,
the high pressure washer shuts down.
The fault is signalled by indicator light F ) flashing.
6 ) Motor thermal protector activated: the high pressure washer
shuts down.
The fault is signalled by indicator light G ) flashing.
N . B . T o r e s e t t h e f a ul t s ig n a l s , t ur n
p os . " 0
" a n d t h e n b a c k t o p os . " I " .
F or f ur t h e r a s s is t a n c e , c on t a c t t h e t e c h n ic a l s e r v ic e c e n t r e .