Fault-Finding Chart - Lamborghini Caloreclima XILO D 20 MC W TOP U/IT Manual Para El Usuario

Caldera mural a gas alto rendimiento - modulante
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FAULT-FINDING CHART

FAULT
1 NO IGNITION
2 CRACKLING
IGNITION
3 SMELL OF GAS
4 MELL OF
UNBURNT GAS
AND BAD
BURNER
COMBUSTION
5 CONDENSATION
IN THE BOILER
6 COLD
RADIATORS
IN WINTER
CAUSE
A. Gas cock closed
B. "Lock-out" button locked
C. No flame detection
D. No ignition spark
E. Air inside pipes
F. Safety thermostat intervention
A. Irregular flame
B. Insufficient or wrongly adjusted
gas delivery
A. Leak in pipes circuit (inside and
outside boiler)
A. Flue section or height with joint not
suitable
for the boiler
B. Excessive gas consumption - combustion
state is imperfect
C. Flames tend to move away or have
yellow tips
A. Flue cross-section or height not
suitable (excessive size)
B. Boiler operating at low temperature
A. Function selector on summer position
B. Room thermostat set too low or faulty
C. System or radiators closed
D. Circulator blocked
REMEDY
A. Open gas cock
B. Reset by pressing
C. Call technical service
D. Call technical service
E. Repeat ignition
F Wait for the temperature to drop
A. Call technical service
B. Call technical service
A. Call technical service
A. Call technical service
B. Call technical service
C. Call technical service
A Call technical service
B Adjust boiler thermostat at a higher
temperature.
A. Place it in winter position
B. Adjust thermostat at a higher
temperature or replace it.
C. Check if system gate valves and
radiator cocks are opened.
If item C has been checked with
negative result call technical service
D. Call technical service
15