JB Systems Light LYNX II Manual De Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
ENGLISH
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable (number 3 on the picture) that can hold 12 times the weight of the
device when installing the unit. This secondary safety
attachment should be installed in a way that no part of
the installation can drop more than 20cm if the main
attachment fails.
 The device should be well fixed; a free-swinging
mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result
in overheating.
 The operator has to make sure that the safety-relating
and machine-technical installations are approved by
an expert before using them for the first time. The
installations should be inspected every year by a
skilled person to be sure that safety is still optimal.
1. Optional Clamp
2. Special clamp bracket (included)
3. Optional safety cable
HOW TO SET UP THE UNIT
CONTROL PANEL:
1. DISPLAY shows the various menus and the selected functions.
2. LEDS
DMX
On
MASTER
On
SLAVE
On
SOUND
Flashing
3. BUTTONS
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
4. REMOTE CONTROL INPUT: Used to connect a simple CA-8 hand controller while the unit is used in
standalone or master/slave mode.
JB SYSTEMS
®
OPERATION MANUAL
DMX input present
Master mode
Slave mode
Sound activation
3/63
ENGLISH
5. SENSITIVITY: Used to adjust the sensitivity of the micro when the unit is used in standalone or
master/slave mode.
6. DMX INPUT/OUTPUT: used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link
the units together.
7. MAINS CABLE: double-check the mains voltage (should be 230V 50Hz) before inserting the cable!
8. MAINS FUSE: Always replace this fuse with a fuse that has the same characteristics! (250V/2A slow)
MAIN MENU:
 To select any of the functions, press the MENU button up to when the required one is shown on the
display.
 Select the function with the ENTER button (the display blinks).
 Use DOWN and UP button to change the mode.
 Once the required mode is selected, press the ENTER button to confirm. After 8 seconds the display will
automatically return to the main functions without any change. To go back to the functions without any
change press the MENU button for about 2 seconds. The main functions are shown in the chart.
Used to set the starting address in a
DMX setup.
 Press the MENU button until
shown on the display.
 Press the ENTER button, the display
starts blinking.
 Use DOWN and UP buttons to change
the DMX512 address.
 Once the correct address shows on the
display, press the ENTER button to
save it. (or automatically return to the
main functions without any change
after 8 seconds)
To go back to the functions without any
change press the MENU button again for
about 2 seconds for about 2 seconds.
Used to choose the Show mode when
used in standalone or master/slave
mode.
 Press the MENU button until
showing on the display.
 Press the ENTER button, the display
starts blinking.
 Use DOWN and UP buttons to select
one of the available shows:
on the floor. Tilt movement angle
210°.
under ceiling. Tilt movement angle 90°.
projecting to the audience's direction; i.e. in front of the stage. Pan movement angle (left to right to
left): 160°. Tilt movement angle: 90° (60° above horizon; 30° below horizon.)
movement angle (left to right to left):160°. Tilt movement angle: 90° (vertically, front 75°; back 15°)
 Once the right mode shows on the display, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
LYNX-II
JB SYSTEMS
DMX512 Address Setting
is
Show Mode
is
Show 1: Fixture is placed
Show 2: Fixture is fixed
Show 3: Fixture is placed on a podium, in front of the audience. The spot is always
Show 4: Fixture is fixed under ceiling. The spot is mainly projecting in front of the stage. Pan
4/63
®
OPERATION MANUAL
LYNX-II

Publicidad

Tabla de contenido
loading

Tabla de contenido