Installation
Requirements
Before installing your microwave hood combination,
make sure your location meets these requirements. See
the Installation Instructions for details.
Observe all governing codes and ordinances.
A 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused
electrical supply is required. (A time-delay fuse is
recommended.)
It is recommended
that a separate
circuit serving only this appliance be provided.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.
GROUNDING INSTRUCTIONS
For all cord-connected
appliances:
The microwave over must be grounded.
In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an
escape wire for the electric current. The microwave
oven is equipped with a cord having a grounding
wire with a grounding plug. The plug must be
plugged into an outlet that is properly installed and
grounded.
WARNING:
Improper use of the grounding
plug can result in a risk of electric shock.
Consult a qualified electrician or serviceman
if the grounding instructions
are not completely
understood,
or if doubt exists as to whether the
microwave oven is properly grounded.
Do not use an extension cord. If the power supply
cord is too short, have a qualified electrician or ser-
viceman install an outlet near the microwave oven.
@