TECHNICAL FEATURES
DESCRiZiOnE
Methane delivery
B/P delivery
Thermal output
Motor
Trasformer
Total absorbed power
Methane pres sure
B/P pressure
Weight
Power supply
Category
(*) 60Hz operation only with electronic transformer.
PRESSURE CURVES
PRESSURE CURVES/GAS DELIVERY
PRESSURE CURVES: The pressure curves indicate the output in kW according to the
backpressure in the combustion chamber, in mbars.
PRESSURE CURVES/GAS DELIVERY: These curves show the gas pressure, in milli-
bars, (at points Pi and Pt along the gas train) necessary to produce a given
delivery in m 3/h. The pressures have been measured with the burner working and with
a pressure of 0 mbar in the combustion
chamber. If the chamber is pressurized, the gas pressure necessary will be that given
in the diagram plus that in the combustion chamber.
Legend
1 Interception cock - airtight at 1 bar and pressu-
re loss
0,5 mbar.
2 Vibration-damping joint
3 Gas pressure point for pressure reading
4 Gas filter
5 Gas pressure regulator
6 Minimum gas pressure control device (pressu-
re switch)
UK
7 Class A solenoid safety valve. Closure time Tc
≤ 1".
30
Em 3 ST-E
min
1,61
max
3,52
min
0,57
max
1,25
min
16,0
max
35,0
280
11,5
230V-50/60Hz (*) single phase
BASIC GAS TRAIN
8 Class A solenoid safety valve. Closure time Tc ≤ 1".
Ignition power between 10% and 40% of rated ther-
mal
power.
9 Gas delivery regulator, normally incorporated in ei-
ther solenoid valve 7 or 8.
10 Combustion head.
11 Minimum air pressure control device (pressure
switch)
Em 6 n ST-E
2,71
6,24
0,96
2,22
27,0
62,0
100
8/20 - 12/48
300
20
30
12,6
II 2H 3+
M
3
m
/h
3
m
/h
3
m
/h
3
m
/h
kW
kW
W
kV/mA
W
mbar
mbar
kg
M