5.
STORAGE
IMPORTANT:
CHARGE IMMEDIATELY AFTER PURCHASE
kEEP FULLY CHARGED
Charge the Portable Power internal battery immediately upon purchase, after every
use and every 30 days.
All batteries are affected by temperature. The ideal storage temperature is at 70
degrees Fahrenheit. The internal battery will gradually self-discharge (lose power)
over time, especially in warm environments. Leaving the battery in a discharged
state may result in permanent battery damage. To ensure satisfactory performance
and avoid permanent damage, charge the internal battery every month.
6.
SPECIFICATIONS
Internal Battery Type
Nominal Voltage
Capacity
DC Power Outlet (Max. Continuous
Load)
Dimensions (H x W x D)
Product Weight
Maximum Continuous Power
Surge Capacity (Output Wattage)
No Load Current Draw
Wave Form
AC Outlets
Maintenance-free AGM Lead-Acid
12V DC
22 Ah
15A maximum
11.5 x 9.5 x 6.5
18 lbs.
Inverter Specifications
400 Watts
800 Watts
<0.4 Amps
Modified Sine Wave
Two, 120V AC 3-Prong grounded
5