To set up the charging parameters,
turn on the charger disconnected from the battery.
From the No Battery screen it's possibleto change the voltage, current
curve of the charger using the following buttons:
Press
to set the nominal voltage.
E.g. 2, 6, 12, 24, 36, 48, 64, 72 or 80V
e
Press
t
o set the charging curve or
desulphation mode.
e
Press
t
o set maximum charging current
from 5 up to 130A
Desulphation mode settings:
Using
button set the Desulfat mode.
e
Use
button to set the desulphation current.
e
Use
button to set the desulphation cycle time,
from 2h up to 100h.
e
To interrupt the desulphation cycle at any time,
hold
to set the charger in STOP mode.
To set up the date and time, the charger must be switched on and connected
to the battery.
During the charging press
VOLTAGE, CURRENT AND CHARGING CURVE SETTINGS
DATE AND TIME SETTING
four times to view the date and time screen.
10.24.42
80%
Voltage
Current
Batt.Type : WET DEEP
End of Chg: Floating
,
Voltage
Current
Batt.Type : Desulfat
End of Chg: Floating
Desulfation
Time
Current: 45A
x4
Time:
Date:
Code: GOLD0200210120
10.24.42
No
Battery
and
charging
:
24 V
:
85 A
:
-
V
:
45 A
15:30h
10.15.46
09-10-2021
21.