2.6.5 Model 706 Configuration Menu — device Setup
4.5
Menú de Configuración del Modelo 706 —
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
Display Config
Advanced Config
Factory Config
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
I/O Config
Display Config
Advanced Config
Factory Config
Probe Model:
Level Units:
Inches
7YD Coax HTHP
7YF Sngl Rod Std
Feet
Millimeters
7YG Sngl Rod Std
Centimeters
7YJ Sngl Rod HTHP Cages
Meters
7YL Sngl Rod HP Cages
7YM Sngl Rod HP Tanks
Distance Units:
7YN Sngl Rod HTHP Tanks
Inches
7YP Coax HP
7YS Coax Steam
Feet
Millimeters
7YT Coax Std
7Y1 Sngl Flex Std
Centimeters
Meters
7Y2 Sngl Flex Bulk
7Y3 Sngl Flex HP
Temperature Units:
7Y5 Twin Flex Bulk
Celsius
7Y6 Sngl Flx HTHP Cage
Fahrenheit
7Y7 Twin Flex Clad
Probe Coating: (7yF only)
None (Bare)
PFA Coated
SP57-646 Eclipse
®
Transmisor Radar de Onda Guiada - F
Measurement Type:
Level Only
Interface and Level
System Units
Volume and Level
Flow
Measurement Type:
Level Only
Interface and Level
Volume and Level
System Units
Flow
Probe Mount:
NPT
BSP
Flange
NPT/Flushing
BSP/Flushing
Flange/Flushing
Hygienic
Probe Length:
12 inches to 100 feet
(30 cm to 30 m)
Level Offset:
-25 feet to +75 feet
(-7.6 m to 22.9 m)
Dielectric Range:
Below 1.7
1.7 to 3.0
3.0 to 10
Above 10
Volume Setup:
fieldbus
™
OUNDATION
justes de Dispositivo
Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Distance Units:
Inches
Feet
Millimeters
Centimeters
Meters
Interface Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Upper Thickness Units:
Inches
Feet
Millimeters
Centimeters
Meters
Temperature Units:
Celcius
Fahrenheit
Volume Units:
Cubic Feet
Cubic Inches
Cubic Meters
Gallons
Milliliters
Liters
Barrels
Vessel Type:
Rectangular
Horizontal/Flat
Horizontal/Ellipse
Horizontal/Spherical
Spherical
Vertical/Flat
Vertical/Ellipse
Vertical/Spherical
Vertical/Conical
Custom Table
Probe Model:
7YD Coax HTHP
7YF Sngl Rod Tanks
7YG Sngl Rod Cages
7YJ Sngl Rod HTHP Cages
7YL Sngl Rod HP Cages
7YM Sngl Rod HP Tanks
7YN Sngl Rod HTHP Tanks
7YP Coax HP
7YS Coax Steam
7YT Coax Std
7Y1 Sngl Flex Std
7Y2 Sngl Flex Bulk
7Y3 Sngl Flex HP
7Y5 Twin Flex Bulk
7Y6 Sngl Flx HTHP Cage
7Y7 Twin Flex Clad
Probe Coating: (7yF only)
None (Bare)
PFA Coated
Probe Mount:
NPT
BSP
Flange
NPT/Flushing
BSP/Flushing
Flange/Flushing
Hygienic
Probe Length:
12 inches to 100 feet
(30 cm to 30 m)
Level Offset:
-25 feet to +75 feet
(-7.6 m to 22.9 m)
Dielectric Range:
Below 1.7
1.7 to 3.0
3.0 to 10
Above 10
Upr Dielectric:
1.2 to 10
Vessel Dimensions:
(not used with Custom Table)
Radius
Ellipse Depth
Conical Height
Width
Length
Custom Table Setup:
Custom Table Type:
Linear
Spline
Level Input Source:
Keypad
Sensor
CUSTOM TABLE VALUES:
Up to 30 Pairs of
Level/Volume Data