4.5
Menú de Configuración del Modelo 706 —
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
I/O Config
Display Config
Advanced Config
Factory Config
Level Units:
Probe Model:
Inches
7YD Coax HTHP
Feet
7YF Sngl Rod Std
Millimeters
7YG Sngl Rod Std
Centimeters
7YJ Sngl Rod HTHP Cages
Meters
7YL Sngl Rod HP Cages
7YM Sngl Rod HP Tanks
Distance Units:
7YN Sngl Rod HTHP Tanks
Inches
7YP Coax HP
Feet
7YS Coax Steam
Millimeters
7YT Coax Std
Centimeters
7Y1 Sngl Flex Std
Meters
7Y2 Sngl Flex Bulk
7Y3 Sngl Flex HP
Temperature Units:
7Y5 Twin Flex Bulk
Celsius
7Y6 Sngl Flx HTHP Cage
Fahrenheit
7Y7 Twin Flex Clad
Probe Mount:
NPT
BSP
Flange
NPT/Flushing
BSP/Flushing
Flange/Flushing
Hygienic
Probe Coating:
None (Bare)
PFA Coated
Probe Length:
12 inches to 100 feet
(30 cm to 30 m)
Dielectric Range:
Below 1.7
1.7 to 3.0
3.0 to 10
Above 10
Flow Setup:
40
Measurement Type:
Level Only
Interface and Level
Volume and Level
Flow
System Units
Flow Units:
Cubic Ft/Second
Cubic Ft/Minute
Cubic Ft/Hour
Gallons/Minute
Gallons/Hour
Mil Gallons/Day
Liters/Second
Liters/Minute
Liters/Hour
Cubic Meters/Hour
Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Head Units:
Inches
Feet
Millimeters
Centimeters
Meters
Flow Element:
Palmer-Bowlus Flume
Flume Channel Width:
4 inches
6 inches
8 inches
10 inches
12 inches
15 inches
18 inches
21 inches
24 inches
27 inches
30 inches
Parshall Flume
Flume Channel Width:
1 inch
2 inches
3 inches
6 inches
9 inches
12 inches
18 inches
24 inches
36 inches
48 inches
60 inches
72 inches
96 inches
120 inches
144 inches
SP57-646 Eclipse
justes de Dispositivo
V notch Weir
TOTALIZER SETUP:
V-notch Weir Angle:
Units:
22.5°
Cubic Feet
30°
Gallons
45°
Mil Gallons
60°
Liters
90°
Mil Liters
120°
Cubic Meters
Rect Weir with Ends
NON-RESET
0 to 215.0 feet
TOTALIZER:
(0 to 65 m)
Units:
Rect Weir w/o Ends
Cubic Feet
0 to 215.0 feet
Gallons
(0 to 65 m)
Mil Gallons
Liters
Cipolletti Weir
Mil Liters
0 to 215.0 feet
Cubic Meters
(0 to 65 m)
Multiplier:
Generic Equation
1
K
10
L
100
C
1,000
n
10,000
100,000
Custom Table
Custom Table Type:
Value (read only)
RunTime (read only)
Linear
Spline
RESETTABLE
CUSTOM TABLE
TOTALIZER:
VALUES:
Mode:
Up to 30 Pairs of
Disabled
Head/Flow Data
Enabled
Reference Distance:
Units:
11.8 inches to 100 feet
Cubic Feet
(30 cm to 30 m)
Gallons
Mil Gallons
Maximum Head
Liters
(calculated, read only)
Mil Liters
Cubic Meters
Maximum Flow
Multiplier:
(calculated, read only)
1
Low Flow Cutoff:
10
0 to 9999999 cubic ft/min
100
1,000
10,000
100,000
Value (read only)
RunTime (read only)
Reset
®
Transmisor Radar de Onda Guiada - F
fieldbus
™
OUNDATION