AC CURRENT MEASUREMENTS
I CAUTION:
Do not make current measurements
on the 10A scale for
I
longer than 30 seconds. Exceeding 30 seconds may cause damage to
the meter and/or the test leads.
1. Insert the black test lead banana plug into the
negative (COM) jack.
2. For current measurements
up to 200mA AC, set
the function switch to the 200m AAC position and
insert the red test lead banana plug into the (mA)
jack.
3. For current measurements
up to 10A AC, set the
function switch to the 10A range and insert the red
test lead banana plug into the (10A)jack.
4. Remove power from the circuit under test, then
open up the circuit at the point where you wish to
measure current.
jv.v_ i
_ j
:,,1 ii
5. Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to the positive side of the circuit.
6. Apply power to the circuit.
7. Read the current in the display. The display will indicate the proper
decimal point and value.
13