Descargar Imprimir esta página

Craftsman 82141 Manual Del Propietário página 8

Ocultar thumbs Ver también para 82141:

Publicidad

Idiomas disponibles

Idiomas disponibles

Diode T est
Continuity Check
Battery Test current
Input Impedance
ACV Bandwidth
DCA voltage
drop
Display
Overrange
indication
Polarity
Measurement
Rate
Low Battery Indication
Battery
Fuses
Operating
Temperature
Storage
Temperature
Operating
Humidity
Storage
Humidity
Operating
Altitude
Weight
Size
Safety
Test current of 1 mA maximum, open circuit
voltage 2.8V DC typical
Audible signal will sound if the resistance is less
than approximately
30£2
9V (6mA); 1.5V (100mA)
>1M£2
45Hz to 450Hz
200mV
3 ½ digit, 2000 count LCD, 0.5" digits
"1" is displayed
Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity.
2 times per second, nominal
"_"
is displayed if battery voltage drops below
operating voltage
one 9 volt (NEDA 1604) battery
mA, IJA ranges; 0.2A/250V fast blow
A range; 10A/250V fast blow
41°F to 104°F (5°C to 40°C)
-4°F to 140°F (-20°C to 60°C)
Max 80% up to 87°F (31°C) decreasing linearly
to 50% at 104°F (40°C)
<80%
7000ft. (2000) meters maximum.
9.17 oz. (260g).
4.78" x 2.38" x 1.57" (121.5mm x 60.6mm x
40mm)
For indoor use and in accordance with
Overvoltage Category II, Pollution Degree 2.
Category II includes local level, appliance,
portable equipment,
etc., with transient
overvoltages
less than Overvoltage
Category III.

Publicidad

loading