HEAT SENTRY SYSTEM
This range hood is equipped with an advanced Heat Sentry
system that monitors excessive temperature
and automatically
adjusts the fan to the appropriate setting.
1) If the fan is on
the Heat Sentry system will increase the
fan setting when the temperature is elevated. If the temperature
continues to rise, the Heat Sentry system will continue to increase
the fan setting until the temperature is stabilized or reduced.The
flashing light above the fan button shows the Heat Sentry system
fan setting. Once the temperature has reduced, the Heat Sentry
system will change the fan to the original setting.
2) If the fan is off the Heat Sentry system will automatically turn
the fan on to its highest speed when the temperature is above
normal. When the Heat Sentry system is on, the light above the
high speed fan button will flash on and off. After the temperature
has lowered to normal, the fan speed will be reduced until the
temperature has stabilized, then the fan will turn off.
-
Note: Canadian version does not have this function.
-
FUSES
RANGE HOOD CONTROL BOARD
MAIN
LIGHT
FUSE
FUSE
Page 4
MAKE-UP AIR DAMPER
The hood is compatible with Broan Make-Up Air Damper Model
MD6T or Model MD8T (optional). Purchase separately.
Make the connection to the Make-Up Air Damper with low voltage
wiring, as shown. See Make-Up Air Damper instructions
for
additional information.
l
®
o
/
BACK OF HOOD
/
I
LOW-VOLTAGE CONNECTOR
FOR MAKE-UP AIR DAMPER
RANGE
HOOD
LOW-VO LTAG E
WIRES
¢----
120
VAC__
MAKE-UP AIR
DAMPER
DAMPER
MOTOR
REMOTE CONTROL
The hood is compatible with Broan RF Remote Control Model
BCR1 (optional). Purchase separately.
The Range Hood Control
Board contains a Main Fuse and a
Fuse to protect the controls from power surges. If a fuse has
opened (blown), the green fan setting or light setting indicators will
not operate properly when the fan or light buttons are pressed, and
the fan and lights will not turn on.
New fuses can be purchased at your local electronic supply store.
Use 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-
type fuses.
To replace a fuse (by qualified person(s):
1. Disconnect power at service entrance.
2. Remove filters and bottom pan.
3. Remove and inspect fuse. If it is not open (blown), additional
diagnostics are needed.