Technical Data
Supply circuit (A1, A2)
Operating voltage U
(U
: AC/DC 24 V)
B
N
Residual ripple DC Uss
Rated power
Peak current I
Peak
Operating voltage U
(U
: AC 42 - 48 V)
B
N
Rated power
Operating voltage U
(U
: AC 115 - 120 V)
B
N
Rated power
Operating voltage U
(U
: AC 230 V)
B
N
Rated power
Rated frequency AC
Output circuit (S11, S21)
Output voltage
Short-circuit behavior
Input circuits S12 and S52/S22
Input voltage U
e
Input current I
e
Input peak current I
e,peak
Line resistance per channel
Release time t
R
Recovery time t
W
Interrupt time of U
(test pulses), t
e
Period of interrupt time
Synchronous time t
S
Input circuit S34
Input voltage U
e
Input current I
e
Input peak current I
e peak
Line resistance
Response time t
A1
Response time t
A2
Ready time t
B
Interrupt time of U
(test pulses), t
e
Period of interrupt time
Output circuit
Continuous current I
n
Switching voltage U
n
Switching load
Contact equipment
Contact material
Utilization category acc. EN 60947-5-1
Short-circuit protection
Conditional short-circuit current to EN 60947-5-1
Mechanical endurance
General data
Creepage and clearance between circuits
Rated surge voltage
Overvoltage category
Contamination level
Rated voltage
Test voltage U
Protection degree EN 60529 (housing / terminals)
Ambient temperature working range / storage range
Weight DC devices / AC devices
Terminals and connection
Single-core or finely stranded
Stripping length
Finely stranded with wire-end ferrule to DIN 46228
Max. tightening torque
(
)
*
see diagram 1
4
TP
TP
SNA 4044K/KM
SNA 4064K/KM
SNA 4043K/KM
SNA 4063K/KM
50 Hz
eff
min.
typ.
20.4 V
1.6 W / 2.9 VA
AC 35.7 V
2.3 W / 2.6 VA
AC 97.8 V
2.2 W / 2.5 VA
AC 195.5 V
2.1 W / 2.4 VA
50 Hz
absolutely short-circuit proof
19.2 V
25 mA
max. 5 + ((1,176 × U
) – 1) × 200
/ U
B
N
25 ms
19.2 V
5 mA
150 ms
50 ms
350 ms
25 ms
4 Enabling paths (NO, positively driven)
3 Enabling paths (NO, positively driven)
1 Signaling path (NC, positively driven)
AgSnO
2
AC-15: Ue AC 230 V, Ie 5 A
DC-13: Ue DC 24 V, Ie 5 A
max 8 A / < 100 A²s
1000 A
6
1010
switching operations
acc. EN 60664-1
4 kV
III
3 external, 2 internal
AC 300 V
2 kV
IP 40 / IP 20
-25C to +65C / -25C to +70C
0.21 / 0.25 kg
screw-type terminals
1 x 0.2 - 2.5 mm² / 2 x 0.2 - 0.75 mm²
max. 8 mm
1 x 0.25 - 2.5 mm² / 2 x 0.25 - 0.5 mm²
0.5 to 0.6 Nm
max.
26.4 V
2.4 V
1.5 A
AC 52.8 V
AC 126.5 V
AC 253 V
60 Hz
DC 40 V
26.4 V
100 mA
10 ms
750 ms
1 ms
26.4
50 mA
25
350 ms
100 ms
1 ms
(
)
8 A
*
AC 230 V
2000 VA
spring-type terminals
2 x 0.2 - 1.5 mm²
2 x 0.25 - 1.5 mm² (trapezoid crimping)
--