Installation
Instructions
INSTALLING THE WATER LINE CON SOME
MODELS)
BEFORE YOU BEGIN
Recommended
COl)per
water
supply
kits
are
WX8X2,
_'_X8X3
or _,_X8X4,
depending
on the
amom_t
of
tubing
you
need.
Approved
plastic
water
sui)ply
lines
are
GE SmartConnect'"
Refrigerator
Tubing
(WX08X10002,
WX08X10006,
WX08X10015
and
WX08X10025).
When
COlmecting
your
refl'igerator
to a GE
Reverse
Oslnosis
_4'ater
Systeln,
the
only
approved
installation
is with
a GE
RVKit.
For
other
reverse
osmosis
water
systems,
tollow
the
manufi_cturer's
recommendations.
This
water
line
installation
is not
warranted
by the
refrigerator
or icemaker
manufi_cturer.
Follow
these
inst_ uctions
carefidlv
to minimize
the
risk
of expensive
water
damage.
_4'ater
halnlner
(water
banging
in the
pipes)
in house
plmnbing
can
cause
damage
to refl'igerator
parts
and
lead
to water
leakage
or flooding.
Call
a qualified
plmnber
to correct
water
hammer
before
installing
the
water
supply
line
to the
refl'igerator.
To prevent
burns
and
product
damage,
do not
hook
up the
water
line
to the
hot
water
line.
If you
use your
refl'igerator
before
cmmecting
the
water
line,
make
sm'e
the
icemaker
power
switch
is
in the
0 (off) position.
Do
not
install
the
icemaker
tubing
in areas
where
temperatm'es
tall
below
freezing.
When
using
any
electrical
device
(such
as a power
drill)
during
installation,
be sm'e
the
device
is double
insulated
or grotmded
in a manner
to prevent
the
hazard
of electric
shock,
or is batte_
T powered.
All installations
must
be in accordance
with
local
i)hunbing
code
requirelnents.
WHAT YOU WILL NEED
• Copper
or GE SmartConnect
'_' Refrigerator
Tubing
kit,
l/4"
outer
diameter
to connect
the reli'igerator
to the water
sui)i)ly. If using
COl)per, be sm'e both
ends
of the tubing
are cut square.
To determine
how much
tubing
you need:
measure
the distance
fl'om
the water
wdve on the back
of the
refl'igerator
to the water
sui)ply
pipe.
Then
add
8' (2.4 m). Be sure
there
is sulticient
extra
tubing
(about
8' [2.4 m] coiled
into
3 turns
of about
10" [25 cm] diameter)
to allow the refl'igerator
to
inove out fl'om
the wall after installation.
GE SmartConnect'"
Refl'igerator
Tubing
Kits are
available
in the following
lengths:
2' (0.6 m)
- _43X08X10002
6' (1.8 m)
- WX08X10006
15' (4.6 m)
- WX08X10015
25' (7.6 m)
- WX08X10025
Be sure that the kit w)u select
allows at least 8' (2.4 m)
as described
above.
NOTE:
The
only
GE
approved
plastic
tubing
is that
supplied
in GE
SmartComaect
'_' Refrigerator
Tubing
kits.
Do
not
use
any
other
plastic
water
supply
line
because
the
line
is under
pressure
at all times.
Certain
types
of plastic
will crack
or rupture
with
age
mad cause
water
dmnage
to your
home.
14