Descargar Imprimir esta página

How To Restart After Losing Power; Unload The Machine - Milnor E-P Plus Manual Del Usuario

Publicidad

How to Restart after Losing Power

2.1.7.
The control remembers the formula and step it was executing if power fails or if the wall
disconnect is turned off while the machine is operating in automatic mode.
Display or Action
PRESS START TO RUN
STEP xx - FORMULA yy

Unload the Machine

2.1.8.
DANGER 3 : Entangle and Sever Hazards—Contact with goods being processed can
cause the goods to wrap around your body or limbs and dismember you. The goods are normally
isolated by the locked cylinder door.
• Do not touch goods inside or hanging partially outside the turning cylinder.
When the formula ends or is terminated, the cylinder coasts for 25 seconds if the last step was a
bath step. If the last step was an extract, the coast time may be as much as 180 seconds. Do not
attempt to open the door early.
Display or Action
UNLOCKING THE DOOR
PLEASE WAIT
WAITING TO UNLOAD
U
Explanation
On most machine models, this display appears when power is
restored. The formula and step which were in progress when
power was interrupted are shown.
Resumes the formula at the displayed formula and step. If the
\
outage occured in a bath step, level and temperature (if
commanded) must again be satisfied, even if these were already
satisfied before power was lost. Any commanded chemicals will
be injected again.
If the outage occured during the drain part of a bath step, the
bath step will be repeated, then followed by the next commanded
step.
If the outage occured during an extract step, the previous bath
will be repeated before the extract step begins.
Explanation
display during the last 15 seconds of coast, or during the entire
coast time if the formula was manually terminated.
At the end of the coast time, the operator alarm sounds.
Silences the operator alarm. The door unlocks so you can unload
x
the machine.
— End of BICJVO03 —
11
Chapter 2. Normal Operation
PELLERIN MILNOR CORPORATION

Publicidad

loading

Este manual también es adecuado para:

E-p express