Descargar Imprimir esta página

Neptun NPRP 4600 Manual De Instrucciones Original página 13

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Anleitung_NPRP_4600_SPK7__ 10.06.13 15:48 Seite 13
IMPORTANT
The equipment and packaging material are not toys.
Do not let children play with plastic bags, foils or small
parts. There is a danger of swallowing or suffocating!
Rain barrel pump
n
Aluminium tube, long
n
Aluminium tube, short
n
Aluminium tube with attachment hook
n
Swiveling connection with stopcock
n
Original operating instructions
n
3. Intended use
It is intended mainly for pumping off water from rain
barrels.
The equipment you have purchased is designed to
pump water with a maximum temperature of 35 °C.
This equipment must never be used for other liquids,
especially not for engine fuels, cleaning agents and
other chemically-based products!
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and for
many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of water
with a natural, muddy bottom, place the equipment in
a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In this
case the equipment's anticipated life will be greatly
shortened because the equipment was not designed
for continuous loading.
The equipment may only be used for its intended
purpose. Any other use is deemed to be a case of
misuse. The user/operator and not the manufacturer
will be liable for any damage or injuries of any kind
which result from such misuse.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping
lubricating oil/lubricant.
4. Technical data
Mains connection
Power rating
Max. pumping rate
with 25.4 mm (1") hose
with 16 mm rain barrel pipe
Max. delivery head
Max. submersion depth
Max. water temperature
Hose connectionapprox. 26.4 mm (G 3/4) male thread
Max. size of foreign bodies:
Switching point height: ON
Switching point height: OFF
Protection type.
5. Before starting
5.1 Assembly (Figs. 3 to 6)
1. Screw the aluminium tube (Item 5) to the pump
connection (Fig. 3).
2. Screw the aluminium tubes (Items 5, 6 and 7)
together (Figs. 4 and 5).
3. Screw the connection (Fig. 8) to the aluminium
tube (Item 7) (Fig. 6).
5.2 Fitting the pump to a rain barrel
Use the attachment hook to fit the pump to the rain
barrel (Fig. 6, Item B).
Note!
When installing, never hang the equipment by the
discharge line or by the power cable. The equipment
must be hung up with the provided carry handle or it
must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft
always must be free of sludge and other
accumulations of dirt. If the water level is too low, the
sludge in the shaft can quickly dry out and hinder the
equipment from starting. It is necessary therefore to
check the equipment regularly (carry out trial start-
ups).
Note:
The pump shaft should be of sufficient size to enable
the floating switch to move freely.
GBR
230 V ~ 50 Hz
300 W
4600 l/h
1750 l/h
11 m
7 m
35°C
Ø 35 mm
max. approx. 50 cm
min. approx. 15 cm
IPX8
13

Publicidad

loading

Este manual también es adecuado para:

41.704.36