Section 4: Operation
the
Engine
[.
Turn OFF and unphg all electrical loads from generator
pane[ receptacles. NEVER start or stop engine with
electrical devices plugged [n and turned ON.
2.
Let engine run at no:load for several minutes to
stabilize internal
temperatures
of engine and generator.
3.
Turn engine off according
to instructions
given [n the
engine operator's
manual
4.
Hove fuel vaHve to "Off"
position.
[
m
Use each receptacle
to operate
[20Vo[tAC,
single-phase,
60 Hz eHectr[ca[ [oads reqor[ng
up to 2_400 watts
(2.4 kW)
at 20 Amps of current.
Use cord sets that are rated
for
[ 25 Volt AC loads at 20 Amps (or greater).
G E N E RATO R ADAPTE
R
CORD
SET
The generator
comes with a 25' generator
adapter
cord set
designed to provide two sets of [20Vo[t_ 20 Amp outlets from
one
120Volt, 20Amp
duplex receptacle
(Figure 6).The
generator
adapter
cord set provides a convenient
supply of
emergency
power so that your generator
can be operated
safely outside.
. NEVER attempt to power a device requiring more amperage
than generator
or receptacle can supply.
. DO NOT overload the generator: See "Don't Overload
_enerator'.
[ 20 Volt AC, 20 Amp,
Duplex
Each duplex receptacle
(Figure 5) is protected
against
overload
by a push-to-reset
circuit
breaker.
//
'<
e
The maximum
load on each outlet
is 20 Amps.The
maximum
total load on both black wire outlets
or white
stripe wire outlets
is 20 Amps.
NOTE:
Follow all safety precautions
when
connecting
any
extension
cord or device to the generator.