COLD
WEATHER
Under certain weather conditions
(temperatures
bellow
40°F [4°C] combined with high humidity), your generator
may experience
icing of the carburetor
and/or the
crankcase breather system.To reduce this probiem_ you
need to perform
the following:
i.
Make sure generator
has cieam fresh fuel
2.
Open fuei vaive (turn vaive to open position).
3.
Use SAE 5Wo30 oii (see engine user's manuai).
4.
Check oii ievei daiiy or after every eight (8) hours of
operation.
S.
Maintain generator
following"Maintenance
Schedule"
in engine user's manual.
6.
Shelter unit from elements.
Creating
aTemporary
Cold Weather
I.
In an emergency, use the original shipping carton.
2.
Cut off top carton flaps and one long side of carton to
expose muffler side of uniL If required_ tape up other
sides of carton to fit over generator
as shown in
Figure 7.
Typical Genel acor
Shown
NOTE:
If required_ remove wheel kit to fit carton over
generator
as shown in Figure 7.
3.
Cut appropriate
slots to access
receptacles
of unit.
4.
Face exposed
end away from wind and elements.
S.
Locate generator
as described
in the section
"Generator
Location".
Keep exhaust
gas from entering
a confined
area through
windows,
doors, ventilation
intakes or other openings.
WARNING
Operate
generator
ONLY outdoors.
Keep exhaust
gas from
entering
a confined
area through
windows,
doors, ventilation
intakes
or other
openings,
DO NOT operate generator" inside an>' building or enclosure
(even if doors or windows
are open), including the generator
compartment
of a recreational
vehicle (RV).
Start generator
as described
in the section "Starting
the Engine", then place carton
over generator.
Keep at
least S ft. (152 cm) clearance
on all sides of generator
including overhead
with shelter
in place.
WARNING
7,
8.
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least S ft (152 cm) clearance on all sides of generator
including overhead.
Remove shelter when temperatures are above 40°F [4°C].
Remove shelter when temperatures
are above 40°F
[4°C1.
Turn engine OFF and let cool two (2) minutes before
refueling.VVipe
up any spilled fuel.
Creating
a Permanent
Cold Weather
I.
Build a structure
that will enclose
three
sides and the
top of the generator,
making sure muffler side of
generator
is exposed.
NOTE:
Structure
should hold enough
heat created
by the
generator
to prevent
icing problem.
2.
DO NOT enclose
generator
any more
than shown
in
Figure 7.
NOTE:
If a wheel
kit is installed
on the generator,
enlarge
shelter
accordingly.
3.
Follow steps 3 through
8 as described
previously
in
"Creating
aTemporary
Cold _A/eather Shelter".