Charging procedure
The charging process with the Wallbox eM4 Single is described below.
Proceed as follows:
1 Park the vehicle so that its charging inlet can be
easily reached with the charging cable's charging
connector.
When the charge point of the wallbox is ready
x
for charging, the status indicator pulsates
green (display: 1 cycle).
2 Prepare the charging cable of the wallbox and the
vehicle's charging inlet.
J Open the charging inlet at the vehicle and plug
in the charging connector.
J Open the charging socket lid on the wallbox
and plug in the charging connector.
3 Check the status indicator of the wallbox.
When the vehicle is connected and recognised,
x
the status indicator lights up static green.
NOTE
Authentication of the Wallbox eM4 Single
Depending on the model version, the Wallbox eM4 Single can be configured differently during installation.
Controller: A Controller can be operated as a stand-alone wallbox or with a backend.
x
Controller with Extender: A Controller can be operated with one or more Extender wallboxes as a charging
x
group in a backend or without a backend.
Stand-alone Extender: An Extender configured for stand-alone operation is operated without a backend.
x
If it is necessary to authenticate the charging operation via an RFID card, carry out the following steps 4 to 6. If
authentication is not required, go to step 7.
4 Check the status indicator of the wallbox.
If the charging operation has to be enabled
x
using an RFID card, a blue chase light is
shown dynamically on the status indicator.
Charging procedure
23