17 ACCESSORIES
17.1 Central support
The central support (Fig. 34) provides a central securing point
also for the single-piece sliding guide.
17.2 Key-operated release
The external release can be installed with the lever system
(Fig. 35 ref. A) or the key system (Fig. 35 ref. B). See instructions
in par. 6.3 and par. 7.5.
17.3 Safety edge CN60E
The use of the safety edge with conductive element, is
facilitated because the control unit (Fig. 36 ref
housed on board the operator.
Procedure:
- Grip the rear door with one hand.
- Pull gently, separating it from the plastic housing.
- Grip the ceiling light with one hand.
- Pull gently, separating it from the plastic housing.
- Unscrew the 4 screws in the 4 corners of the plastic housing.
- Separate it from the base.
- House the control unit as shown in Fig. 36.
- First hook on the two fastening clips on the coupling on the
base.
- Then press lightly until you can hear the hooking snap sound.
- For the connections, refer to the specific instructions for the
CN60E safety edge, and Fig. 27 of these instructions.
17.4 Battery kit
Fig. 34
The buffer battery kit will activate the automated system in
the event of a power cut. The batteries are housed inside the
operator (Fig. 37 ref.
To install, consult the specific instructions.
The batteries come into operation when a power cut
occurs.
Fig. 35
) can be
After installing the batteries, connect the male
connector to the J12 female connector on the E600
control board.