Use Of The Heat Shielding Mat; Operation With Portable Generator; Inspection - Shizuoka Seiki Co. VAL6KBE1S Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

■ Shut-Down Operation
CAUTION
• To disconnect the power plug from the AC outlet, please make sure that the fan motor is stopped.
Turn "OFF" the operating switch, and the
heater flame will be extinguished, then the
fan motor will also automatically stop after
about three (3) minutes, and finally the oper-
ating lamp will turn off.

3-3. Use of the Heat Shielding Mat

To avoid unexpected fire or trouble, NEVER
use the heater on combustible flooring un-
less the heat shielding mat, which is avail-
able as an option, is used.

3-4. Operation with Portable Generator

WARNING
The heater operates within the voltage range
of 207 Volts to 253 Volts. Before plugging the
heater into the generator, the output voltage
of generator should be verified.
4

Inspection

CAUTION
8
• After the operation is shut down, please make sure that the flame is completely extin-
guished before leaving the place.
Observations
• Before operating the heater from a portable generator, please confirm that the generator
has been properly connected to the ground earth. To operate the generator without proper
grounding may result in electrical shock. Please refer to the owner's manual supplied by
the generator's manufacturer.
• Before starting any inspection or service, to avoid electric shock, please make sure the
heater is shut down and that the power cord is disconnected.
• When cleaning the heater, please wear gloves to prevent possible injury.
Operating switch "OFF"
O N
O F F
RU N
M I S F I R E
Heat shielding mat
If the voltage does not measure in this range,
the heater should not be plugged into the gen-
erator.

Publicidad

Tabla de contenido
loading

Tabla de contenido