If the pump discharges into a pressurized line, the installation of a non-return valve is recommended.
ð
When installing pump and accessories it is recommended the installation of check valves in order to
facilitate maintenance operations. Fig. 13 shows a typical installation.
ð
Please observe the following instructions when pumping liquids that tend to cristallize or suspensions
that tend to sediment:
keep suspension correctly agitated in order to prevent sedimentation
avoid installation of vertical lines over the pump discharge nozzle
before stopping the pump start a washing cycle of the pump and pipes
design suction and discharge lines should permit complete emptying
3. START-UP
Electrical connection:
• connect electric motor to mains (power source)
• check the direction of rotation of the electric motor; an arrow on the electric motor shows the correct direc-
tion of rotation
The electric motor should be connected by qualified personnel only!
WARNING
Don't start the pump with the suction and/or discharge check valves closed
Don't close check valves while the pump is in operation
Before starting the pump check the following points:
Check pumphead for the correct filling of the hydraulic liquid
Check metering pump for overpressure protection (pressure relief valve installation)
Verify that all hydraulic connections are correctly tight
Position adjustment knob at "zero" flow rate (see para 1.3.1)
Start the pump without discharge pressure and increase progressively the flow rate up to 100%
Check the hydraulic chamber for possible air bubbles intrapped in the liquid pushing the replenishing valve un-
til no air is blown out
Keep the pump in operation for few minutes
Increase progressively the pressure until the required performances are reached
WARNING
DON'T EXCEED THE MAXIMUM PERFORMANCE STENCILLED ON THE PUMP LABEL
If no pressure gauge is fitted on the plant, the installation of a temporary pressure gauge is recom-
mended in order to check that the actual pressure at the start-up doesn't exceed the maximum allow-
able pressure
ð
pumps are self-priming, however some priming problem could be encountered with pumps having very low
flow rate, small plunger diameter, with back pressure valves installed and in presence of high discharge
pressure. In these cases it could be necessary to aid priming purging air from pumphead and suction line.
WARNING
If the pumped liquid is toxic, poisonous, aggressive, flammable or for any reason danger-
ous, use particular care avoiding accidental leakages through gaskets or pipes during start-
up or maintenance operations
Moreover follow all the recommendations of the manufacturer for handling and the local
laws relevant to safety during handling and disposal of dangerous
DosingPump.ir
rev. 4.0 EN
substances.
6