Descargar Imprimir esta página

Cebora POWER SPOT 5700 Manual De Instrucciones página 19

Soldadora de descarga de condensadores
Ocultar thumbs Ver también para POWER SPOT 5700:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
4. Fully insert the earth cable plug into the socket B and turn clockwise.
5. Fully insert the gun plug into the socket C and turn clockwise.
6. Turn on the welding machine using the E switch. (start-up and shutdown should not be repeated frequently,
because dissipating the energy contained in the capacitors may cause overheating and damage).
7. To limit exposure to the magnetic field, keep the gun cable on the side of the hand holding it, avoiding wrapping the
cable around.
5.1
Description of the equipment
A
Display for the setting and control of welding operations
B
Positive output terminal
C
Negative output terminal
D
Torch trigger connector
E
Main switch
F
Fuse Ø 6.3x32 (delayed type). The equipment is fitted with a 12A-T fuse.
G
Knob for the setting and control of welding operations
5.2
Gun description
K
Gun body
L
Grip
M
Control cable
N
Welding current cable
O
Welding command button (works only with the gun pressed against the sheet metal)
P
Force setting indicator
Q
Force adjustment screw (increases when turned clock wise)
Ring to hold spacer Z
R
3301291
3300103/D
F
A
E
D
B
Fig. 1
G
C
19

Publicidad

loading

Este manual también es adecuado para:

2156