CONVERSION
INSTRUCTIONS
,
Replace it with the NG orifice, and then tighten.
Make sure you are using the correct
orifice,
marked
"1.4".
(Fig. 24)
Natural Gas Hose Connection
1.4
Fig.24
1. Remove the LP gas hose and regulator
using a wrench, and attach the natural gas
hose in it's place. (Fig. 25)
LP gas hose and regulator
NG Hose
Fig. 25
Adjust valve control
screw
,
,
3.
Pull all the knobs off of valve stems. Adjust
the screw in the valve hole using the flathead
screwdriver
(C). Turn screws two complete
turns (720 ° ) counterclockwise.
(Fig. 26)
Press all the knobs back onto valve stems.
After all the conversions
are complete,
return
heat diffusers to firebox, followed
by the
grates and warming
rack. To check gas leaks,
please follow use and care procedure
on page
30.
I
/
Valve hole
Fig. 26
13