TROUBLESHOOTING
EN
PROBLEM
The power unit fails
to start.
The power unit stops
working.
The speed makes
no changes when
switching the Eco/
Turbo speed.
The speed goes
down automatically
when suffer con-
tinuous heavy load
and maintain at low
speed level, which
could be identified
through running
sound.
WARRANTY
EGO WARRANTY POLICY
Please visit the website www.poweredbyego.com for full terms and conditions of the EGO Warranty policy.
10
UNIVERSAL POWER UNIT-PU2700/PU2700S
CAUSE
◾
The electronic ON/OFF button is
not activated.
◾
The battery pack(s) is not
engaged in place in the battery
compartment.
◾
The Bowden cable is not pulled
enough to trigger the switch.
◾
Other unidentified causes.
◾
The battery pack(s) is depleted.
◾
The power unit is over loaded.
◾
The battery pack(s) is over
temperature.
◾
The power unit is over
temperature.
◾
Other unidentified causes.
◾
If the surrounding is too noisy, it
is difficult to recognize changes.
◾
Incorrect operation steps.
◾
The power unit features an
automatic adjustment function for
overload protection.
SOLUTION
◾
Press the electronic ON/OFF button till green color
lights.
◾
Attach the battery pack(s) in the battery
compartment, and press it until you hear a "click".
◾
The travel distance of the Bowden cable should
meet the designed requirement of 20 mm.
◾
Contact a qualified service technician for repair.
◾
Charge the battery pack(s).
◾
Reduce the working load.
◾
Reduce the working load or replace with the larger
capacity battery pack(s).
◾
Avoid using the battery pack(s) in high temperature
environment.
◾
Check and clean the air cleaner.
◾
Reduce the load and avoid using the power unit in
high temperature environment.
◾
Contact a qualified service technician for repair.
◾
Let go the Bowden cable to stop the machine,
switch the speed again. Measure the speed
difference to further check if necessary.
◾
Restart the power unit following the section
"STARTING THE POWER UNIT".
◾
If still not work, contact EGO service center for
repair.
◾
Reduce load according to actual situation, and then
the power unit will returns to full speed state.