Descargar Imprimir esta página

Xylem Rule 401C Guía De Instrucciones página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
DESCRIPTION
Powerful and long lasting, Rule Tournament Series Cartridge Pumps offer
outstanding performance as well as the versatility of replacing the motor
cartridge if the motor expires. The cartridge feature also allows complete access
to the impeller for easy cleaning and maintenance. Replacing the motor cartridge
only allows the fitting and hose to remain totally intact.
TO CHANGE MOTOR CARTRIDGE
Block off the thru-hull before removing the motor cartridge.
Turn off power to the pump then disconnect wiring to cartridge.
Press cartridge button, twist counterclockwise and pull motor cartridge
straight up.
Reconnect wire to new motor cartridge.
Align the arrows and press the new motor cartridge down firmly. Twist motor
housing clockwise until cartridge locks in place. A "click" should be heard
when the cartridge is locked.
WARNING. The operator of the vessel should
ensure the motor cartridge is in the fully locked
position at all times when the vessel is in the water.
Failure to place the motor cartridge in the fully locked position
could result in water intrusion, flooding, property damage, severe
personal injury and/or death.