c. Install the supply socket in the wall. The requirements for the socket are as follows:
250V/10A, single phase, three electrodes. It is recommended to place the socket on the
right above the heater. The height of the socket to ground shall not be less than 1,8m.
d. If the bathroom is too small, the heater can be installed at another place without sun-
scorched and rain-drenched. However, in order to reduce the pipeline heat losses, the
installation position of the heater shall be closed to the location for use of water as near as
possible.
2. Connection of pipelines:
a. The dimension of each pipe part is G1/2.
b. Connection of one-way safety valve: install the one-way safety valve attached with the
machine at the water inlet of the main machine. (Pay attention to keep the installed
drainage flexible pipes of the safety valve sloping downward and connected with the
atmosphere.
c. In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided
with the machine must be added at the end of the threads.
d. If then users want to realize a multi-way supply system, refer to the method shown
for connection of the pipelines.