METHODS OF USE
1. First, open any one of the outlet valves at the outlet of the water heater, then, open the
inlet valve. The electric water heater begins to be filled with water. When there is water
coming out of the outlet valve normally, it implies that the heater has been filled fully with
water, and the outlet valve can be closed.
Note: During normal operation, the inlet valve shall be sent in status of "open".
2. Insert the supply plug into the socket, the two indicator lights are on at this time.
3. This machine can automatically control the temperature. When the water temperature
inside the machine has reached the set temperature (it is set to 75ºC), it will be turned off
automatically, and step into the status of thermal insulation; when the water temperature
is decreased to a certain point, it will be turned on automatically to restore the heating,
and the use of hot water will not be interrupted. When the heater is switched off
automatically, the heating indicator will turn off.
CAUTIONS
1. The supply socket must be earthed reliably. The rated current of the socket shall not be
lower than 10A. The socket and plug shall be kept dry to prevent electric leakage.
Inspect frequently whether the plugs contact well with the socket. Inspect method is as
follows: insert the power supply plug into the socket, after using for half an hour, shut
down the unit and pull the plug out, and inspect the plug whether it scalds hand. If it
scalds (over 50ºC), please change another well contacted socket to avoid the plug being
damaged, fire or other personnel accidents results from the bad contacting.
2. For the places or the wall where the water may splash, the installation height of the
socket shall not be lower than 1,8m.
3. The wall in which the electric water heater is installed shall be able to bear the load
more than two times of the heater filled fully with water without distortion and cracks.
Otherwise, other strengthening measures shall be adopted.
4. The one-way safety valve attached with the machine must be installed at cold water
inlet of this machine.