3. Intended use
The equipment you have purchased is designed to
pump water with a maximum temperature of 35 °C.
This equipment must never be used for other liquids,
especially not for engine fuels, cleaning agents and
other chemically-based products!
Before you use the pump, clarify any possible special
conditions which need to be fulfilled for the
installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protected
power circuit, moisture sensors for switching off the
pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you have
any doubt.
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and for
many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of water
with a natural, muddy bottom, place the equipment in
a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In this
case the equipment's anticipated life will be greatly
shortened because the equipment was not designed
for continuous loading.
The equipment may only be used for its intended
purpose. Any other use is deemed to be a case of
misuse. The user/operator and not the manufacturer
will be liable for any damage or injuries of any kind
which result from such misuse.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping
lubricating oil/lubricant.
4. Technical data
Mains connection
Power rating
Max. pumping rate
Max. delivery head
Max. submersion depth
Max. water temperature
Hose connection
approx. 33.3 mm (G 1) IG
Max. size of foreign bodies:
Power cable
5. Before starting
5.1 Installation
The equipment can be installed either:
Stationary with a rigid pipe line
n
or
Stationary with a flexible hose line
n
Connect the pressure hose or pipe to the
n
pressure connector (1) using a suitable
connector.
The equipment must be fastened with the
n
supplied rope (Fig. 1/Item 6) to the suspension
eyes (Fig. 1/Item 2).
Note:
The pump shaft should measure at least
40 x 40 x 50 cm so that the floating switch can move
freely.
5.2 Mains connection
The equipment you have purchased comes with an
earthing-pin plug. The equipment is designed for
connection to a socket outlet with earthing contact for
230 V ~ 50 Hz. Make sure that the socket-outlet is
sufficiently fused (at least 6 A) and in good working
order. Insert the power plug in the socket-outlet and
the equipment is ready for operation.
Important!
To rule out danger, this work must be left strictly to a
specialist electrician or Customer Service.
GBR
230 V ~ 50 Hz
800 W
6000 l/h
32 m
8 m
35°C
Ø 2,5 mm
15 m
11