Do not use solvents, or cleaning products with aggressive
substances (highly chlorinated, corrosive, acidic, abrasive, etc...)
or tools that may damage the surfaces; before restarting ensure
no products used for cleaning have been left in the oven .
4.3
BURNER AIR FILTER CLEANING (only T75G)
After 900 hours of cooking, the message"CLEAN FILTER" is
displayed to clean the burner air filter.
The operator may continue working by pressing Return (fig. 31 item
16) or type the code written inside the filter holder (fig. 37 item C)
and reset land 900 hours.
If the operator chooses to press RETUR N, the message CLEAN
FILTER will appear at each start-up, this allows the current cooking
cycle to be completed. The option is presented again at START.
If the operator chooses to press OK (fig.31 item, 15) the entry screen
to edit INTERNAL CODE FILTER to reset the 900 hours is
accessed. Enter the 4 - digits code by selecting the desired figure with
the up /down arrow keys and press OK then proceed to enter other
figures . A message will display the success or failure of the operation
WARNING!
Failure to clean the filter may compromise
the efficiency and safety of the oven. Remove the finned coil cover
and the filter cloth from the base with a screwdriver in the slot on the
edge of the lid (fig. 37)
The filter cloth (fig. 37 item F) can be cleaned by rinsing, water jet
treatment or beating and let to dry.
Read and remember the 4 code numbers written inside the filter
holder (fig. 37 item C)
Insert the filter cloth into the finned cover by readjusting the side
with lower density facing air intake and hook up the cover at the
base in the default position.
Restart the machine and edit the filter internal code if requested on the
keyboard to complete operation.
4.4
PERIODS OF INACTIVITY
If the appliance is to be unused for a long period:
- Disconnect it from the power supply.
- Stop gas supply.
- Cover it to protect it from dust.
- Air the room from time to time.
- Clean it before reusing.
Prior to operation after the period of non-use repeat the procedure laid
.
down in section 3.5.1