Technical data boiling water storage heater:
• Connection:
• Installation high:
• Voltage supply:
• max. power consumption:
• Type of proteairction:
• Relative humidity:
• Standby power loss (switched on):
• Standby power loss (switched off):
Sanitary data:
• Boiling water storage heater capacity:
• Available storage heater volume at 100 °C:
• Flow pressure:
– min.
– recommended
• Operating pressure:
• Test pressure:
• Flow rate at 0.3 MPa flow pressure
- Mixed water:
- Boiling water:
• Ambient temperature:
• Boiling water temperature
The actual temperature may differ slightly due to different ambient
pressures
• Heating time from 10 °C to 100 °C:
• Clamping length:
• Water connection at storage heater:
• Water connection at fitting:
The enclosed filter system must be used in regions with a
carbonate hardness above 10 °KH.
Therelevant water supplier can provide information on the water
hardness.
Thermical disinfektion of the fitting is possible.
Signalisations
Status
Storage heater-LED Fitting-LED
Initialisation
white
Boiler heating up
red, flashing
Ready for use
red, permanent
Holiday mode
orange, flashing
cooling down
Holiday mode
orange, permanent
Child-lock
-
deactivation process
Child-lock
-
deactivated
Pot filler
-
deactivation process
Pot filler
-
Error
purple,
flashing/permanent
Wall socket with earth wire, protected
via a 10 A fuse
max. 2000m above sea level
230 V AC / 50 Hz
M: approx 3 l
L: approx 5.5 l
0.2 – 0.5 MPa
max. 0.8 MPa
approx. 6 l/min
approx. 3 l/min
0 °C – 40 °C
M: approx. 20 min
L: approx. 30 min
max: 60mm
Cold water from service valve
Boiling water from storage heater
-
-
-
-
-
red, flashing
red, permanent
yellow, flashing
yellow, permanent
purple,
flashing/permanent
Flush pipes thoroughly before and after installation (observe
EN 806).
2200 W
Adjust bypass of filterhead according to local carbonate
IP X4
hardness and connect filter cartridge.
max. 95%
The carbonate hardness can be tested by using the enclosed test
M: 14 W
strip or the relevant water supplier can provide information on the
L: 15,7 W
carbonate hardness.
1 W
Important note: The volume of water in the storage heater will
expand as it is heated. The expansion water must drip out
M: 4 l
at funnel of safety assembly.
L: 7 l
This process is necessary and normal.
Control:
0.2 MPa
The cooler/carbonator is set for operation with the S-Size filter
cartridge (Prod no.: 40 404 001) at the factory.
For operation with other filter cartridges the cooler/carbonator must be
1.6 MPa
switched over, see also page 7.
Button
Briefly press PROG button (PRG flashes)
100 °C
Briefly press RESET button to access programming for
litre specification (00000 flashes)
Keep pressing PROG button until required position is
reached (00000 digit flashes)
Keep pressing RESET button until required digit is
reached (00600 digit flashes)
Cold water
Keep pressing PROG button to exit menu (PRG
disappears and set value appears)
Unlock the child safety device to get boiling water, see A.
Key combination for filling pots with boiling water, see B.
To get cold or hot water, see C.
Activation of the holiday mode, see D.
Note:
In order to prevent incorrect operation and for protection against injury,
we recommend affixing the sticker provided.